Home › Engine / Hybrid System · 3UR-FE › EMISSION CONTROL › AIR PUMP

AIR PUMP > INSPECTION

for Preparation Click here



1. INSPECT AIR PUMP ASSEMBLY


    A158408E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    0.4 to 1.0 Ω
    1 - Body ground
    Always
    10 kΩ or higher
    2 - Body ground

    If the result is not as specified, replace the air pump assembly.



    A158406E02
  1. Check the operation of the air pump.

    1. Check that air does not flow from port A to port B.



    2. A158407E04
    3. Apply battery voltage to the connector, and check the air pump operation.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → Terminal 2
      Battery negative (-) → Terminal 1
      Air flows from port A to port B

      If the result is not as specified, replace the air pump assembly.

      NOTICE:
      1. Do not operate the air pump continuously for 2 minutes or more.
      2. When operating the air pump, wait 5 minutes until the pump has cooled down between each operation. If the pump has not cooled down sufficiently, the motor will burn out.