CAN COMMUNICATION SYSTEM > Suspension Control ECU Communication Stop Mode |
| Detection Item | Symptom | Trouble Area |
| Suspension Control ECU Communication Stop Mode | When either condition below is met:
|
|


| 1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
| NEXT | |
| 2.CHECK FOR OPEN IN CAN BUS WIRE (SUSPENSION CONTROL ECU BRANCH WIRE) |
![]() |
w/ AVS
Disconnect the O18 suspension control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O18-30 (CANH) - O18-29 (CANL) | Ignition switch off | 54 to 69 Ω |
![]() |
w/o AVS
Disconnect the O19 suspension control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O19-29 (CANH) - O19-28 (CANL) | Ignition switch off | 54 to 69 Ω |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (SUSPENSION CONTROL ECU - BATTERY AND BODY GROUND) |
![]() |
w/ AVS
Reconnect the cable to the negative (-) battery terminal.
Disconnect the O17 and O18 suspension control ECU connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O17-5 (GND) - Body ground | Always | Below 1 Ω |
| O18-1 (GND) - Body ground |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O17-6 (B) - Body ground | Always | 11 to 14 V |
| O18-10 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
![]() |
w/o AVS
Reconnect the cable to the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
Disconnect the O19 suspension control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O19-22 (GND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O19-24 (B) - Body ground | Always | 11 to 14 V |
| O19-10 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
|
| ||||