DTC C1762 Continuous Electric Current to Exhaust Solenoid |
| DTC Code | Detection Condition | Trouble Area |
| C1762 | With the exhaust valve activated, the vehicle does not go down to the standard vehicle height after 105 seconds have elapsed. |
|

| 1.PERFORM ACTIVE TEST USING TECHSTREAM (REAR GATE SOLENOID) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON, and turn the Techstream main switch on.
Enter the following menus: Chassis / Air suspension / Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Rear Gate Solenoid | Gate solenoid valve/ | ON or OFF | Operation sound of solenoid (clicking sound) can be heard |
|
| ||||
| OK | |
| 2.PERFORM ACTIVE TEST USING TECHSTREAM (REAR LEVELING SOLENOID) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON, and turn the Techstream main switch on.
Enter the following menus: Chassis / Air suspension / Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Rear Leveling Solenoid | Leveling solenoid valve | ON or OFF | Operation sound of solenoid (clicking sound) can be heard |
|
| ||||
| OK | |
| 3.PERFORM ACTIVE TEST USING TECHSTREAM (EXHAUST SOLENOID) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON, and turn the Techstream main switch on.
Enter the following menus: Chassis / Air suspension / Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Exhaust Solenoid | Exhaust solenoid valve | ON or OFF | Operation sound of solenoid (clicking sound) can be heard |
|
| ||||
| OK | |
| 4.INSPECT NO. 1 HEIGHT CONTROL COMPRESSOR (EXHAUST SOLENOID VALVE) |
Turn the ignition switch off.
![]() |
Disconnect Q3 solenoid valve connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (B) - 2 (L) | 20°C (68°F) | 10 to 14 Ω |
Connect the battery positive (+) lead to terminal 1 and the negative (-) lead to terminal 2 of the solenoid valve connector. Then check that the valve makes an operating sound.
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (EXHAUST SOLENOID VALVE - ECU AND BODY GROUND) |
![]() |
Disconnect the O16 ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Q3-1 (B) - O16-8 (SLEX) | Always | Below 1 Ω |
| Q3-1 (B) or O16-8 (SLEX) - Body ground | Always | 10 kΩ or higher |
| Q3-2 (L) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||