DTC P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input |
DTC P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0712 | ATF temperature sensor resistance is less than 79 Ω for 0.5 sec. or more (1 trip detection logic) |
|
| P0713 | ATF temperature sensor resistance is more than 156 kΩ for 0.5 sec. or more and either of the following conditions is met (1 trip detection logic): (A) 388 sec. or more have elapsed after the engine start when engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less. (B) 10 sec. or more have elapsed after the engine start when engine coolant temperature and intake air temperature are more than -29.375°C (-20.875°F). |
|
| Related DTCs | P0712: ATF temperature sensor/Range check (Low resistance) P0713: ATF temperature sensor/Range check (High resistance) |
| Required sensors/Components | ATF temperature sensor |
| Frequency of operation | Continuous |
| Duration | 0.5 seconds |
| MIL operation | Immediately |
| Sequence of operation | None |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| The monitor will run whenever the following DTCs are not present | None |
| The monitor will run whenever this DTC is not present | P0115, P0117, P0118 (ECT (Engine coolant temperature) sensor circuit) P00AC, P00AD, P0110, P0112, P0113 (IAT (Intake air temperature) sensor circuit) |
| Engine coolant temperature or intake air temperature at engine start | -29.375°C (-20.875°F) or less |
| Time after engine start | 388 seconds or more |
| The monitor will run whenever this DTC is not present | P0115, P0117, P0118 (ECT (Engine coolant temperature) sensor circuit) P00AC, P00AD, P0110, P0112, P0113 (IAT (Intake air temperature) sensor circuit) |
| Engine coolant temperature and intake air temperature at engine start | More than -29.375°C (-20.875°F) |
| Time after engine start | 10 seconds or more |
| ATF temperature sensor resistance | Less than 79 Ω |
| ATF temperature sensor resistance | More than 156 kΩ |
| ATF temperature sensor resistance | 79 Ω to 156 kΩ |

| DATA LIST |
Warm up the engine.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List.
According to the display on the Techstream, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| A/T Oil Temperature 1 | No. 1 ATF temperature sensor value/ Min.: -40°C (-40°F) Max.: 215°C (419°F) |
| If value is -40°C (-40°F) or 215°C (419°F), No. 1 ATF temperature sensor circuit is open or shorted |
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or more | Short circuit |
| 1.INSPECT NO. 1 TRANSMISSION WIRE (NO. 1 ATF TEMPERATURE SENSOR) |
![]() |
Disconnect the D41 No. 1 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (OT-) - 9 (OT+) | Always | 79 Ω to 156 kΩ |
| 1 (OT-) - Body ground | Always | 10 kΩ or higher |
| 9 (OT+) - Body ground | Always | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM) |
![]() |
Disconnect the D56 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D56-122 (THO1) - D56-98 (ETHA) | Always | 79 Ω to 156 kΩ |
| D56-122 (THO1) - Body ground | Always | 10 kΩ or higher |
| D56-98 (ETHA) - Body ground | Always | 10 kΩ or higher |
| Result | Proceed to |
| NG | A |
| OK (for 3UR-FE) | B |
| OK (for 3UR-FBE) | C |
|
| ||||
|
| ||||
| A | ||
| ||