FUEL INJECTOR > INSPECTION

for Preparation Click here



1. INSPECT FUEL INJECTOR ASSEMBLY


    A158970E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    11.6 to 12.4 Ω

    If the result is not as specified, replace the injector assembly.



  1. Inspect the injection volume.

    CAUTION:
    1. This test involves high-pressure fuel and electricity. Take all precautions regarding safe handling of both the fuel and the electricity.
    2. Perform this test in a safe area, and avoid any sparks or flames.
    3. Do not smoke.




      C157056E02
    1. Remove the fuel pipe clamp.



    2. A088336E01
    3. Disconnect the fuel tube.



    4. A088228E12
    5. Connect SST to the fuel pipe (the vehicle side).

      SST
      09268-31012   (09268-41500, 95336-08070)



    6. A149192E01
    7. Install the O-ring to the fuel injector.

    8. Install SST and a tube to the fuel injector.

      SST
      09268-31012   (90467-13001, 09268-41300, 09268-41600)

      CAUTION:
      Install a strong rubber tube onto the injector to prevent gasoline from splashing.



    9. A149193E01
    10. Put the injector into a graduated cylinder.

    11. Operate the fuel pump (turn the ignition switch to ON).

    12. Connect SST (wire) to the injector and the battery for 15 seconds, and measure the injection volume with the graduated cylinder. Test each injector 2 or 3 times.

      SST
      09842-30090  

      Standard injection volume:
      97 to 118 cm3 (5.9 to 7.2 cu. in.) per 15 seconds

      Difference between each injector:
      21 cm3 (1.3 cu. in.) or less

      If the injection volume is not as specified, replace the injector assembly.



  1. Check for leakage.



      A149194
    1. In the condition above, disconnect the tester probes of SST (wire) from the battery and check for fuel leakage from the injector.

      Standard:
      1 drop or less in 12 minutes