Home › Vehicle Interior › HEATING / AIR CONDITIONING › COMPRESSOR

COMPRESSOR > INSTALLATION

for Preparation Click here



1. ADJUST COMPRESSOR OIL


I104348E01
  1. When replacing the compressor with a new one, gradually discharge the refrigerant gas from the service valve. Then drain the following amount of oil from the new compressor before installation, so that the amount of oil contained in it is the same as that in the compressor to be replaced.

    HINT:
    New compressors are filled with sufficient oil for the whole cycle. Therefore, it is necessary to drain residual oil from the condenser and cooling unit.

    Standard:
    (The amount of oil inside a new compressor: 190 (+15) cc (6.4 (+0.51) fl.oz.)) - (The amount of oil remaining in the removed compressor) = The amount of oil to be removed when replacing the compressor

    NOTICE:
    1. When checking the compressor oil level, observe the precautions for cooler removal/ installation.
    2. If a new compressor is installed without removing the same amount of oil as is remaining in the vehicle pipes, the amount of oil will be too large. This prevents heat exchange in the refrigerant cycle and will be causes a refrigeration failure.
    3. If the amount of oil remaining in the removed compressor is too low, check for an oil leak.
    4. Use ND-OIL8 or equivalent for compressor oil.



2. INSTALL COOLER COMPRESSOR ASSEMBLY


I104396E01
  1. Install the cooler compressor and 2 stud bolts.

    Torque:
    10 N*m{ 102 kgf*cm , 7 ft.*lbf }

  1. Install the 2 bolts and 2 nuts.

    Torque:
    25 N*m{ 250 kgf*cm , 18 ft.*lbf }

    HINT:
    Tighten the bolts and nuts in the order shown in the illustration to install the cooler compressor.

  1. Connect the connector.



3. CONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE


I104395
  1. Remove the attached vinyl tape from the cooler refrigerant discharge hose.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the cooler compressor.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring on the cooler refrigerant discharge hose.

  1. Connect the cooler refrigerant discharge hose on the cooler compressor with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



4. CONNECT NO. 1 COOLER REFRIGERANT SUCTION HOSE


    I104394
  1. Remove the attached vinyl tape from the cooler refrigerant suction hose.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the cooler compressor.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring on the cooler refrigerant suction hose.

  1. Connect the cooler refrigerant suction hose on the cooler compressor with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



5. INSTALL FENDER APRON MUDGUARD SEAL LH


I104333
  1. Install the seal with the 6 clips.



6. INSTALL FAN & GENERATOR V BELT
  1. Install the fan and generator V belt (Click here).



7. CHARGE REFRIGERANT



I100449E02

NOTICE:
Charge refrigerant in accordance with the equipment manual.

  1. Perform vacuum purging using a vacuum pump.

  1. Charge refrigerant HFC-134a (R134a).

    SST
    09985-20010   (09985-02010, 09985-02050, 09985-02060, 09985-02070, 09985-02080, 09985-02090, 09985-02110, 09985-02130, 09985-02140, 09985-02150)

    Standard:
    860 to 920 g (30.3 to 32.5 oz.)

    NOTICE:
    Do not start the engine before charging it with refrigerant as the cooler compressor does not work properly without sufficient refrigerant. This could cause the compressor to overheat.

    HINT:

    1. The relationship between the refrigerant charge amount and the pressure is as follows.


      I103968E01

    2. High Charge Range:
      If the refrigerant is overcharged, the pressure rises on the high-pressure side. High-pressure cut off frequently occurs. This causes insufficient cooling performance and also insufficient compressor lubrication.
    3. Low Charge Range:
      A shortage of refrigerant causes insufficient cooling performance and low circulation of refrigerant oil, which shortens the compressor life. Operation with insufficient coolant raises the refrigerant temperature and causes heat deterioration of the rubber seals and hoses. Cracking and subsequent refrigerant leakage may occur.


    1. Install the caps onto the service valves on the refrigerant line.



8. WARM UP ENGINE

NOTICE:
Warm up the engine at less than 2000 rpm for 1 minute or more after charging it with refrigerant.



9. INSPECT FOR REFRIGERANT LEAK
  1. After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.

  1. Perform the operation as follows:

    1. Stop the engine.
    2. Secure good ventilation (the halogen leak detector may react to volatile gases other than refrigerant, such as evaporated gasoline or exhaust gas).
    3. Repeat the test 2 or 3 times.
    4. Make sure that some refrigerant remains in the refrigeration system.
      When the compressor is off: approximately 392 to 588 kPa (4 to 6 kgf*cm2, 57 to 85 psi)

    HINT:
    It is impossible for the above pressure to be maintained if there is leakage.



    I042222E14
  1. Using the halogen leak detector, check the refrigerant line, especially at the connection points, for leakage.

  1. If no gas leakage is detected from the drain hose, remove the blower motor from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.

  1. Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.