CONDENSER (w/o Air Cooled Transmission Oil Cooler) > INSTALLATION |
| 1. INSTALL COOLER CONDENSER ASSEMBLY |
![]() |
Install the cooler condenser with the 2 bolts, as shown in the illustration.
| 2. CONNECT AIR CONDITIONING TUBE ASSEMBLY |
![]() |
Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.
Install the O-ring on to the air conditioning tube.
Connect the air conditioning tube on to the cooler condenser with the 2 bolts.
| 3. CONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
![]() |
Remove the attached vinyl tape from the hose and the connecting part of the cooler condenser.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the hose joint.
Install the O-ring on to the discharge hose.
Connect the discharge hose on to the cooler condenser with the bolt.
| 4. INSTALL RADIATOR ASSEMBLY (for 1UR-FE) |
Install the radiator assembly (Click here).
| 5. INSTALL RADIATOR ASSEMBLY (for 3UR-FE) |
Install the radiator assembly (Click here).
| 6. INSTALL RADIATOR ASSEMBLY (for 3UR-FBE) |
| 7. CHARGE REFRIGERANT |

Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

Install the caps onto the service valves on the refrigerant line.
| 8. WARM UP ENGINE |
| 9. INSPECT FOR REFRIGERANT LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation as follows:
![]() |
Using the halogen leak detector, check the refrigerant line, especially at the connection points, for leakage.
If no gas leakage is detected from the drain hose, remove the blower motor from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.