WIPER SWITCH > INSPECTION |
| 1. INSPECT WIPER SWITCH |
![]() |
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B-2 (+B) - B-3 (+1) | MIST | Below 1 Ω |
| B-1 (+S) - B-3 (+1) | OFF | Below 1 Ω |
| B-1 (+S) - B-3 (+1) | INT | Below 1 Ω |
| B-2 (+B) - B-3 (+1) | LO | Below 1 Ω |
| B-2 (+B) - B-4 (+2) | HI | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| A-2 (EW) - A-3 (WF) | OFF | 10 kΩ or higher |
| A-2 (EW) - A-3 (WF) | ON | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| A-2 (EW) - B-5 (WR) | WASH (Rear wiper switch OFF) | Below 1 Ω |
| A-2 (EW) - B-5 (WR) A-2 (EW) - A-7 (+1R) | OFF | 10 kΩ or higher |
| A-2 (EW) - A-6 (C1R) | INT-LO | Below 1 Ω |
| A-2 (EW) - A-7 (+1R) | ON-HI | Below 1 Ω |
| A-2 (EW) - B-5 (WR) A-2 (EW) - A-7 (+1R) A-7 (+1R) - B-5 (WR) | WASH (Rear wiper switch ON) | Below 1 Ω |
Check the intermittent operation.
Connect the positive (+) voltmeter terminal to terminal 3 (+1) of the B connector and the negative (-) voltmeter terminal to terminal 2 (EW) of the A connector.
Connect the positive (+) battery lead to terminal 2 (+B) of the B connector and the negative (-) battery lead to terminals 2 (EW) of the A connector and 1 (+S) of the B connector.
Turn the wiper switch to the INT position.
Connect the positive (+) battery lead to terminal 1 (+S) of the B connector for 5 seconds.
Connect the negative (-) battery lead to terminal 1 (+S) of the B connector. Operate the intermittent wiper relay and check the voltage between terminals 3 (+1) of the B connector and 2 (EW) of the A connector.

Check the operation (front washer).
Turn the wiper switch off.
Connect the positive (+) battery lead to terminal 2 (+B) of the B connector and the negative (-) battery lead to terminals 1 (+S) of the B connector and 2 (EW) of the A connector.
Connect the positive (+) voltmeter terminal to terminal 3 (+1) of the B connector and the negative (-) voltmeter terminal to terminal 2 (EW) of the A connector. Turn the washer switch on and off, and check the voltage between terminals 3 (+1) of the B connector and 2 (EW) of the A connector.