Home › General › SPECIFICATIONS › BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS

BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS > SERVICE DATA



VSC OFF Switch 
Item
Tester Connection
Switch Condition
Specified Condition
VSC OFF switch
6 - 9
Pressed
Below 1 Ω
Not pressed
10 kΩ or higher

Stop Light Control Relay (for BRK NO. 1) 
Tester Connection
Switch Condition
Specified Condition
3 - 4
Battery voltage applied to terminals 1 and 2
10 kΩ or higher
Battery voltage not applied to terminals 1 and 2
Below 1 Ω
3 - 5
Battery voltage not applied to terminals 1 and 2
10 kΩ or higher
Battery voltage applied to terminals 1 and 2
Below 1 Ω

Stop Light Control Relay (for BRK NO. 2) 
Tester Connection
Switch Condition
Specified Condition
3 - 4
Battery voltage applied to terminals 1 and 2
10 kΩ or higher
Battery voltage not applied to terminals 1 and 2
Below 1 Ω