AIR CONDITIONING SYSTEM > TERMINALS OF ECU |
| CHECK AIR CONDITIONING AMPLIFIER |

Disconnect the H24, H67 and z13 air conditioning amplifier connectors.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| H24-1 (IG+) - Body ground | P - Body ground | Ignition power supply | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |||
| H24-14 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| H24-21 (B) - Body ground | R - Body ground | Battery power source | Always | 11 to 14 V |
| H67-20 (RGND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| H67-24 (+B2) - Body ground | LG - Body ground | Battery power source | Always | 11 to 14 V |
Reconnect the H24, H67 and z13 air conditioning amplifier connectors.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| H24-5 (TAM) - H24-13 (SG-2) | V - G | A/C ambient temperature sensor signal | Ignition switch ON at 25°C (77°F) | 1.35 to 1.75 V |
| Ignition switch ON at 40°C (104°F) | 0.9 to 1.2 V | |||
| H24-8 (LOCK) - H24-13 (SG-2) | SB - G | A/C compressor lock sensor signal | Engine is running Blower switch LO A/C switch ON | Pulse generation (see waveform 1) |
| H24-9 (PRE) - Body ground | Y - Body ground | A/C pressure sensor signal | Refrigerant pressure: normal | 0.5 to 4.8355 V |
| H24-10 (S5-3) - Body ground | R - Body ground | Power supply for pressure sensor | Ignition switch ON | 4.5 to 5.5 V |
| H24-11 (CANH) - H24-14 (GND) | B - W-B | Hi-level CAN bus line | Ignition switch ON | Pulse generation (see waveform 2) |
| H24-12 (CANL) - H24-14 (GND) | W - W-B | Lo-level CAN bus line | Ignition switch ON | Pulse generation (see waveform 3) |
| H24-13 (SG-2) - Body ground | G - Body ground | Ground for ambient temperature sensor | Always | Below 1 Ω |
| H24-17 (AC1) - H24-14 (GND) | B - W-B | Idle-up request signal | Engine idling Magnet Clutch is not engaged | 11 to 14 V |
| Engine idling Magnet Clutch is engaged | Below 1 V | |||
| H24-18 (MHTR) - H24-14 (GND) | L - W-B | Mirror heater relay drive signal | Mirror heater switch OFF→ON | 11 to 14 V → Below 1 V |
| H24-20 (MGC) - H24-14 (GND) | P - W-B | A/C compressor magnetic clutch operation signal | Ignition switch ON Blower switch LO A/C switch OFF | 11 to 14 V |
| Ignition switch ON Blower switch LO A/C switch ON | Below 1 V | |||
| H24-23 (BLW) - H24-14 (GND) | LG - W-B | Blower motor control signal | Ignition switch ON Blower switch LO | Pulse generation (see waveform 4) |
| H24-27 (ACT) - H24-14 (GND) | L - W-B | A/C compressor magnetic clutch on permit signal | Engine idling → Accelerator pedal depressed (Air conditioning cut signal output when engine load increases rapidly) | 11 to 14 V → Below 2 V |
| H24-29 (TR) - H24-34 (SG-1) | G - B | Room temperature sensor signal | Ignition switch ON Front side interior temperature: 25°C (77°F) | 1.8 to 2.2 V |
| H24-32 (TSP) - Body ground | L - Body ground | Passenger side solar sensor signal | Ignition switch ON Solar sensor subjected to electric light | 0.8 to 4.3 V |
| H24-33 (TSD) - Body ground | P - Body ground | Driver side solar sensor signal | Ignition switch ON Solar sensor subjected to electric light | 0.8 to 4.3 V |
| H24-34 (SG-1) - Body ground | B - Body ground | Ground for room temperature sensor | Always | Below 1 Ω |
| H24-37 (LIN1) - H24-14 (GND) | SB - W-B | LIN communication signal | Ignition switch ON | Pulse generation |
| H24-38 (RDEF) - H24-14 (GND) | R - W-B | Defogger relay drive signal | Defogger switch OFF→ON | 11 to 14 V → Below 1 V |
| H24-39 (CFN+) - H24-14 (GND) | V - W-B | Condenser fan relay drive signal | Ignition switch ON Condenser fan OFF→ON | 11 to 14 V → Below 1 V |
| H24-40 (D) - H24-14 (GND) | GR - W-B | Deicer relay drive signal | Deicer switch OFF→ON | 11 to 14 V → Below 1 V |
| H67-1 (RBUS) - H67-21 (RBUG) | V - G | BUS IC control signal | Ignition switch off → ON | Pulse generation |
| H67-4 (TEC) - H67-19 (SGND) | R - L | Rear evaporator temperature sensor signal | Ignition switch ON Evaporator temperature at 0°C (32°F) | 1.7 to 2.1 V |
| H67-6 (SG-5) - Body ground | BR - Body ground | Ground for seat blower switch | Always | Below 1 Ω |
| H67-7 (SG-6) - Body ground | P - Body ground | Ground for rear room temperature sensor | Always | Below 1 Ω |
| H67-8 (S5-2) - H67-6 (SG-5) | SB - BR | Power supply for seat blower switch | Ignition switch ON | 4.5 to 5.5 V |
| H67-9 (SHD+) - H67-20 (RGND) | W - W-B | Driver seat blower drive signal | Ignition switch ON | Pulse generation |
| H67-10 (SHP+) - H67-20 (RGND) | BE - W-B | Passenger seat blower drive signal | Ignition switch ON | Pulse generation |
| H67-13 (RLIN) - H67-20 (RGND) | B - W-B | LIN communication signal | Ignition switch ON | Pulse generation |
| H67-15 (AD-4) - H67-20 (RGND) | GR - W-B | Driver seat blower switch signal | Ignition switch ON Driver seat blower switch 0 position | 4.5 to 5.5 V |
| Ignition switch ON Driver seat blower switch 3 position | Below 1 V | |||
| H67-16 (AD-5) - H67-20 (RGND) | W - W-B | Passenger seat blower switch signal | Ignition switch ON Passenger seat blower switch 0 position | 4.5 to 5.5 V |
| Ignition switch ON Passenger seat blower switch 3 position | Below 1 V | |||
| H67-17 (TR) - H67-7 (SG-6) | L - P | Rear room temperature sensor signal | Ignition switch ON Rear side interior temperature: 25°C (77°F) | 1.8 to 2.2 V |
| H67-19 (SGND) - Body ground | L - Body ground | Ground for rear evaporator temperature sensor | Always | Below 1 Ω |
| H67-21 (RBUG) - Body ground | G - Body ground | Ground for BUS IC | Always | Below 1 Ω |
| H67-22 (BLWH) - H67-20 (RGND) | P - W-B | Blower motor control signal | Ignition switch ON Blower switch LO | Pulse generation (see waveform 5) |
| H67-23 (RBBU) - H67-21 (RBUG) | Y - G | Power supply for BUS IC | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | |||
| z13-2 (BUS G) - Body ground | - | Ground for BUS IC | Always | Below 1 Ω |
| z13-3 (BUS) - z13-2 (BUS G) | - | BUS IC control signal | Ignition switch off → ON | Pulse generation |
| z13-4 (B BUS) - z13-2 (BUS G) | - | Power supply for BUS IC | Ignition switch off | Below 1 V |
| z13-4 (B BUS) - z13-2 (BUS G) | - | Ignition switch ON | 11 to 14 V | |
| z13-5 (SGA) - Body ground | - | Ground for evaporator temperature sensor | Always | Below 1 Ω |
| z13-6 (TEA) - z13-5 (SGA) | - | A/C evaporator temperature sensor signal | Ignition switch ON Evaporator temperature at 0°C (32°F) | 1.7 to 2.1 V |
| z13-6 (TEA) - z13-5 (SGA) | - | Ignition switch ON Evaporator temperature at 15°C (59°F) | 0.7 to 1.3 V |
![]() |
Waveform 1: Using an oscilloscope
| Terminal Name | LOCK - SG-2 |
| Tester Range | 200 mV/DIV., 10 ms./DIV. |
| Condition | Engine is running Blower switch LO A/C switch ON |
![]() |
Waveform 2 (Reference) : Using an oscilloscope
| Terminal Name | CANH - GND |
| Tester Range | 1 V/DIV., 10 μsec./DIV. |
| Condition | Ignition switch ON |
![]() |
Waveform 3 (Reference) : Using an oscilloscope
| Terminal Name | CANL - GND |
| Tester Range | 1 V/DIV., 10 μsec./DIV. |
| Condition | Ignition switch ON |
![]() |
Waveform 4 : Using an oscilloscope
| Terminal Name | BLW - GND |
| Tester Range | 1 V/DIV., 500 μsec./DIV. |
| Condition | Ignition switch ON Blower switch LO |
![]() |
Waveform 5 : Using an oscilloscope
| Terminal Name | BLWH - RGND |
| Tester Range | 1 V/DIV., 500 μsec./DIV. |
| Condition | Ignition switch ON Blower switch LO |
| CHECK INTEGRATION CONTROL AND PANEL |

Disconnect the H45 integration control and panel connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| H45-16 (IG+) - H45-1 (GND) | P - W-B | Ignition power supply | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |||
| H45-1 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| H45-9 (OFF) - H45-10 (AUTO) | GR - LG | Steering pad switch signal | Always | 10 kΩ or higher |
| Steering pad switch push to AUTO | Below 2.5 Ω | |||
| Steering pad switch push to OFF | 313 to 345 Ω | |||
| Steering pad switch push to TEMP+ | 950 to 1050 Ω | |||
| Steering pad switch push to TEMP- | 2955 to 3266 Ω |
Reconnect the H45 integration control and panel connector.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| H45-3 (STX) - H45-1 (GND) | SB - W-B | LIN communication signal | Ignition switch ON | Pulse generation |
| CHECK AIR CONDITIONING CONTROL PANEL |

Disconnect the S4 air conditioning control panel connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| S4-1 (IG) - S4-4 (E) | P - W-B | Ignition power supply | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |||
| S4-4 (E) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
Reconnect the S4 air conditioning control panel connector.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| S4-5 (RLIN) - S4-4 (E) | GR - W-B | LIN communication signal | Ignition switch ON | Pulse generation |