Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM

DTC    B1412/12    Ambient Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The thermistor assembly (ambient temperature sensor) is installed in front of the condenser to detect the ambient temperature which is used to control the air conditioner "AUTO" mode. This sensor is connected to the air conditioning amplifier and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the air conditioning amplifier. The resistance of the thermistor assembly (ambient temperature sensor) changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies voltage (5 V) to the thermistor assembly (ambient temperature sensor) and reads voltage changes as the resistance of the thermistor assembly (ambient temperature sensor) changes.

DTC Code
DTC Detection Condition
Trouble Area
B1412/12
Open or short in ambient temperature sensor circuit
  1. Thermistor assembly (ambient temperature sensor)
  2. Harness or connector between thermistor assembly (ambient temperature sensor) and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM


E147166E04


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM (AMBIENT TEMPERATURE SENSOR)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Air Conditioner / Data List / Ambient Temp Sensor.

  1. According to the display on the Techstream, read the Data List.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temp Sensor
    Ambient temperature sensor /
    Min.: -23.3°C (-9.94°F)
    Max.: 65.95°C (150.71°F)
    Actual ambient temperature is displayed
    Open in circuit: -23.3°C (-9.94°F)
    Short in circuit: 65.95°C (150.71°F)

    OK:
    The display is as specified in the normal condition.


    Result 
    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to Problem Symptoms Table)
    B
    OK (When troubleshooting according to the DTC output)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
A


2.INSPECT THERMISTOR ASSEMBLY (AMBIENT TEMPERATURE SENSOR)


    E147989E02
  1. Remove the thermistor assembly (ambient temperature sensor) (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    15°C (59°F)
    2.45 to 2.88 kΩ
    20°C (68°F)
    1.95 to 2.30 kΩ
    25°C (77°F)
    1.60 to 1.80 kΩ
    30°C (86°F)
    1.28 to 1.47 kΩ
    35°C (95°F)
    1.00 to 1.22 kΩ
    40°C (104°F)
    0.80 to 1.00 kΩ
    45°C (113°F)
    0.65 to 0.85 kΩ
    50°C (122°F)
    0.50 to 0.70 kΩ
    55°C (131°F)
    0.44 to 0.60 kΩ
    60°C (140°F)
    0.36 to 0.50 kΩ

    HINT:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.
    3. As the temperature increases, the resistance decreases (see the graph).

  1. Reinstall the thermistor assembly (ambient temperature sensor).



NG
REPLACE THERMISTOR ASSEMBLY (AMBIENT TEMPERATURE SENSOR) (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)


    E127564E02
  1. Disconnect the A18 thermistor assembly (ambient temperature sensor) connector.

  1. Disconnect the H24 air conditioning amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A18-1 - H24-5 (TAM)
    Always
    Below 1 Ω
    A18-2 - H24-13 (SG-2)
    Always
    Below 1 Ω
    A18-1 or H24-5 (TAM) - Body ground
    Always
    10 kΩ or higher
    A18-2 or H24-13 (SG-2) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the air conditioning amplifier connector.

  1. Reconnect the thermistor assembly (ambient temperature sensor) connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER (Click here)