AIR CONDITIONING SYSTEM > Blower Motor Circuit |


| 1.PERFORM ACTIVE TEST USING TECHSTREAM (BLOWER MOTOR) |
Connect the Techstream to DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test/ Blower Motor
According to the display on the Techstream, check blower motor operation while performing the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Blower Motor | Blower motor | Min.: 0, Max.: 31 | - |
| Result | Proceed to |
| NG (blower motor does not operate) | A |
| NG (blower motor operates but does not change speed) | B |
| OK | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT FUSE (HTR) |
![]() |
Remove the HTR fuse from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| HTR fuse | Always | Below 1 Ω |
Reinstall the HTR fuse.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BATTERY AND BODY GROUND) |
![]() |
Disconnect the H41 blower motor connector.
Measure the resistance and voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| H41-3 (GND) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| H41-1 (+B) - Body ground | Always | 11 to 14 V |
Reconnect the blower motor connector.
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BLOWER MOTOR) |
![]() |
Disconnect the H24 air conditioning amplifier connector.
Disconnect the H41 blower motor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| H24-23 (BLW) - H41-2 (S1) | Always | Below 1 Ω |
| H24-23 (BLW) or H41-2 (S1) - Body ground | Always | 10 kΩ or higher |
Reconnect the blower motor connector.
Reconnect the air conditioning amplifier connector.
|
| ||||
| OK | |
| 5.CHECK BLOWER MOTOR (S1 VOLTAGE) |
![]() |
Disconnect the H24 air conditioning amplifier connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H24-23 (BLW) - Body ground | Ignition switch ON | 4.5 to 5.5 V |
Reconnect the air conditioning amplifier connector.
|
| ||||
| OK | |
| 6.INSPECT AIR CONDITIONING AMPLIFIER (BLW VOLTAGE) |
![]() |
Remove the air conditioning amplifier with its connectors still connected (Click here).
Turn the ignition switch to ON.
Turn the blower switch to LO.
Using an oscilloscope, check the waveform.
| Terminal Name | BLW - GND |
| Tester Range | 1 V/DIV, 500 μsec./DIV |
| Condition | Ignition switch ON Blower switch LO |
Reinstall the air conditioning amplifier.
|
| ||||
| OK | ||
| ||