Home › Vehicle Interior › METER / GAUGE / DISPLAY › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Entire Combination Meter does not Operate

for Preparation Click here


DESCRIPTION

This circuit is the power source circuit for the combination meter. This circuit provides 2 power source types: one is a constant power source mainly used as a backup power source, and other is a power source mainly used for signal transmission. The constant power source is mainly used as a backup power source of the meter CPU. However, it is also used for communication. If a voltage of 12 V is not applied to terminal IG+ when the ignition switch is ON, the indicator will not operate.

WIRING DIAGRAM


E146026E02


INSPECTION PROCEDURE

1.INSPECT FUSE (MET, MET-B)


    E159567E01
  1. Remove the MET and MET-B fuses from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    MET fuse
    Always
    Below 1 Ω
    MET-B fuse
    Always
    Below 1 Ω



NG
CHECK FOR SHORTS IN ALL HARNESSES AND CONNECTORS CONNECTED TO FUSE AND REPLACE FUSE
OK


2.CHECK HARNESS AND CONNECTOR (COMBINATION METER - BATTERY AND BODY GROUND)


    E146031E03
  1. Disconnect the H37 meter connector.

  1. Measure the resistance and voltage according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    H37-40 (E1) - Body ground
    Always
    Below 1 Ω

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    H37-18 (B) - Body ground
    Always
    11 to 14 V
    H37-20 (IG+) - Body ground
    Ignition switch ON
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)