Home › Vehicle Interior › METER / GAUGE / DISPLAY › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Operating Light Control Rheostat does not Change Light Brightness

for Preparation Click here


DESCRIPTION

The illumination intensity of the combination meter and accessory meter is increased by turning the knob of the light control rheostat upward, and decreased by turning the knob downward.

WIRING DIAGRAM


E159568E01


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM (LIGHT CONTROL RHEOSTAT)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream ON.

  1. Enter the following menus: Body Electrical / Combination Meter / Data List.

  1. According to the display on the Techstream, read the Data List.

    Combination Meter 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    TAIL Cancel SW*1
    TAIL cancel switch condition/ON or OFF
    ON: TAIL cancel switch ON
    OFF: TAIL cancel switch OFF
    -
    Rheostat value
    Light control rheostat switch input/Min.: 0, Max.: 100
    Light control rheostat switch is Dark (0) → Bright (100)
    Unit: %

    1. *1: w/ TAIL Cancel Switch

    OK:
    Light brightness can be changed within specified range by manual operation.



NG
Go to step 2
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)  

2.INSPECT LIGHT CONTROL RHEOSTAT
  1. Remove the light control rheostat (Click here).



  1. Measure the resistance according to the table below.


    E189760E01


    Standard Resistance:
    w/o TAIL Cancel Switch 
    Tester Connection
    Condition
    Specified Condition
    3 (RV) - 1 (E)
    Downward → Upward
    See illustration
    7 (T) - 1 (E)
    Always
    8 to 12 kΩ
    w/ TAIL Cancel Switch 
    Tester Connection
    Condition
    Specified Condition
    3 (RV) - 1 (E)
    Downward → Upward
    See illustration
    5 (TC) - 7 (T)
    Downward → Upward
    10 kΩ or higher → Below 1 Ω
    7 (T) - 1 (E)
    Always
    8 to 12 kΩ



NG
REPLACE LIGHT CONTROL RHEOSTAT (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)


    E146545E02
  1. Disconnect the H37 meter connector.

  1. Disconnect the J4 rheostat connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    w/o TAIL Cancel Switch 
    Tester Connection
    Condition
    Specified Condition
    H37-1 (RHIG) - J4-7 (T)
    Always
    Below 1 Ω
    H37-2 (TR) - J4-3 (RV)
    Always
    Below 1 Ω
    H37-3 (E2) - J4-1 (E)
    Always
    Below 1 Ω
    w/ TAIL Cancel Switch 
    Tester Connection
    Condition
    Specified Condition
    H37-1 (RHIG) - J4-7 (T)
    Always
    Below 1 Ω
    H37-2 (TR) - J4-3 (RV)
    Always
    Below 1 Ω
    H37-3 (E2) - J4-1 (E)
    Always
    Below 1 Ω
    H37-38 (TC) - J4-5 (TC)
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)