Home › Engine / Hybrid System ยท 3UR-FBE › EMISSION CONTROL › PCV VALVE

PCV VALVE > INSTALLATION

for Preparation Click here



1. INSTALL VENTILATION VALVE SUB-ASSEMBLY


    A158640E01
  1. Apply a light coat of engine oil to the O-ring, and install it to the valve.

    HINT:
    1. When reusing the ventilation valve sub-assembly, inspect the O-ring.
    2. If the O-ring has scratches or cuts, replace the ventilation valve sub-assembly.

  1. Install the ventilation valve sub-assembly.

    Torque:
    5.0 N*m{ 51 kgf*cm , 44 in.*lbf }



2. CONNECT VENTILATION HOSE


A158657
  1. Connect the ventilation hose.



3. INSTALL NO. 2 CYLINDER HEAD COVER


A158538

NOTICE:
Make sure that the No. 2 cylinder head cover is level with the top surface of the intake port of the cylinder head.

  1. Install the No. 2 cylinder head cover.

    HINT:
    1. Align the No. 2 cylinder head cover cutout with the air tube.
    2. Align the No. 2 cylinder head cover with the front water by-pass joint and cylinder head wall.



4. INSTALL INTAKE MANIFOLD
  1. Install the intake manifold (Click here).