CAMSHAFT POSITION SENSOR > INSTALLATION |
| 1. INSTALL VVT SENSOR |
![]() |
Install the 4 sensors with the 4 bolts.
Connect the 4 sensor connectors.
| 2. INSTALL CAMSHAFT POSITION SENSOR |
![]() |
Install the sensor with the bolt.
Connect the sensor connector.
| 3. INSTALL AIR CLEANER HOSE ASSEMBLY |
![]() |
Install the air cleaner with the 2 bolts.
Tighten the hose clamp.
Connect the ventilation hose and vacuum hose.
Connect the MAF meter connector and clamp.
| 4. INSTALL V-BANK COVER SUB-ASSEMBLY |
![]() |
Attach the 2 V-bank cover hooks to the bracket. Then align the 2 V-bank cover grommets with the 2 pins, and press down on the V-bank cover to attach the pins.