Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM

DTC    B1417/17    Rear Evaporator Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The No. 2 air conditioning harness (rear evaporator temperature sensor) is installed on the evaporator in the rear air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and to control the rear air conditioner. It sends signals to the air conditioning amplifier. The signals change in accordance with the resistance of the No. 2 air conditioning harness (rear evaporator temperature sensor). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier applies a voltage (5 V) to the No. 2 air conditioning harness (rear evaporator temperature sensor) and reads voltage changes as changes in the resistance of the No. 2 air conditioning harness (rear evaporator temperature sensor). This sensor is used for frost prevention.

DTC Code
DTC Detection Condition
Trouble Area
B1417/17
Open or short in rear evaporator temperature sensor circuit
  1. No. 2 air conditioning harness (rear evaporator temperature sensor)
  2. Harness or connector between No. 2 air conditioning harness (rear evaporator temperature sensor) and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM


E127591E06


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM (AMBIENT TEMP SENS (REAR))
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Air Conditioner / Data List / Ambient Temp Sens (Rear).

  1. According to the display on the Techstream, read the Data List.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temp Sens (Rear)
    Evaporator fin thermistor /
    Min.: -29.7°C (-21.46°F)
    Max.: 59.6°C (139.28°F)
    Actual rear evaporator temperature is displayed
    Open circuit: -29.7°C (-21.46°F)
    Short circuit: 59.6°C (139.28°F)

    OK:
    The display is as specified in the normal condition.


    Result 
    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to Problem Symptoms Table)
    B
    OK (When troubleshooting according to the DTC output)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPAIR AIR CONDITIONING AMPLIFIER (Click here)
A


2.INSPECT NO. 2 AIR CONDITIONING HARNESS (REAR EVAPORATOR TEMPERATURE SENSOR)


    E127592E07
  1. Remove the No. 2 air conditioning harness .

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    7 (-) - 8 (+)
    -10°C (14°F)
    7.30 to 9.10 kΩ
    -5°C (23°F)
    5.65 to 6.95 kΩ
    0°C (32°F)
    4.40 to 5.35 kΩ
    5°C (41°F)
    3.40 to 4.15 kΩ
    10°C (50°F)
    2.70 to 3.25 kΩ
    15°C (59°F)
    2.14 to 2.58 kΩ
    20°C (68°F)
    1.71 to 2.05 kΩ
    25°C (77°F)
    1.38 to 1.64 kΩ
    30°C (86°F)
    1.11 to 1.32 kΩ

    HINT:
    1. Touching the thermistor even slightly may change the resistance value. Be sure to hold the connector of the thermistor.
    2. When measuring, the thermistor temperature must be the same as the ambient temperature.
    3. As the temperature increases, the resistance decreases (see the graph).

  1. Reinstall the No. 2 air conditioning harness.



NG
REPAIR NO. 2 AIR CONDITIONING HARNESS
OK


3.CHECK HARNESS AND CONNECTOR (NO. 2 AIR CONDITIONING HARNESS - AIR CONDITIONING AMPLIFIER)


    E127593E03
  1. Disconnect the P9 No. 2 air conditioning harness connector.

  1. Disconnect the H67 air conditioning amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P9-8 (+) - H67-4 (TEC)
    Always
    Below 1 Ω
    P9-7 (-) - H67-19 (SGND)
    Always
    Below 1 Ω
    P9-8 (+) or H67-4 (TEC) - Body ground
    Always
    10 kΩ or higher
    P9-7 (-) or H67-19 (SGND) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the air conditioning amplifier connector.

  1. Reconnect the No. 2 air conditioning harness connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPAIR AIR CONDITIONING AMPLIFIER (Click here)