Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM

DTC    B1419/19    Rear Room Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The cooler (duct sensor) thermistor (rear room temperature sensor) is installed in the rear panel to detect the rear room temperature and control the heater and air conditioner AUTO mode. The resistance of the cooler (duct sensor) thermistor (rear room temperature sensor) changes in accordance with the rear room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies a voltage (5 V) to the cooler (duct sensor) thermistor (rear room temperature sensor) and reads voltage changes as changes in the resistance of the cooler (duct sensor) thermistor (rear room temperature sensor).

DTC Code
DTC Detection Condition
Trouble Area
B1419/19
Open or short in rear room temperature sensor circuit
  1. Cooler (duct sensor) thermistor (rear room temperature sensor)
  2. Harness or connector between cooler (duct sensor) thermistor (rear room temperature sensor) and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM


E147166E10


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM (ROOM TEMP SENSOR (REAR))
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Air Conditioner / Data List / Rear Temp Sensor (Rear).

  1. According to the display on the Techstream, read the Data List.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Rear Temp Sensor (Rear)
    Rear room temperature sensor /
    Min.: -6.5°C (20.3°F)
    Max.: 57.25°C (135.05°F)
    Actual rear room temperature is displayed
    Open circuit: -6.5°C (20.3°F)
    Short circuit: 57.25°C (135.05°F)

    OK:
    The display is as specified in the normal condition.


    Result 
    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to Problem Symptoms Table)
    B
    OK (When troubleshooting according to the DTC output)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
A


2.INSPECT COOLER (DUCT SENSOR) THERMISTOR (REAR ROOM TEMPERATURE SENSOR)


    E162297E03
  1. Remove the cooler (duct sensor) thermistor (rear room temperature sensor) (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    15°C (59°F)
    2.45 to 2.88 kΩ
    20°C (68°F)
    1.95 to 2.30 kΩ
    25°C (77°F)
    1.60 to 1.80 kΩ
    30°C (86°F)
    1.28 to 1.47 kΩ
    35°C (95°F)
    1.00 to 1.22 kΩ
    40°C (104°F)
    0.80 to 1.00 kΩ
    45°C (113°F)
    0.65 to 0.85 kΩ
    50°C (122°F)
    0.50 to 0.70 kΩ
    55°C (131°F)
    0.44 to 0.60 kΩ
    60°C (140°F)
    0.36 to 0.50 kΩ

    HINT:
    1. Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.
    3. As the temperature increases, the resistance decreases (see the graph).

  1. Reinstall the cooler (duct sensor) thermistor (rear room temperature sensor).



NG
REPLACE COOLER (DUCT SENSOR) THERMISTOR (REAR ROOM TEMPERATURE SENSOR) (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (REAR ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)


    E127577E02
  1. Disconnect the O15 cooler (duct sensor) thermistor (rear room temperature sensor) connector.

  1. Disconnect the H67 air conditioning amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    O15-1 - H67-17 (TR)
    Always
    Below 1 Ω
    O15-2 - H67-7 (SG-6)
    Always
    Below 1 Ω
    O15-1 or H67-17 (TR) - Body ground
    Always
    10 kΩ or higher
    O15-2 or H67-7 (SG-6) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the air conditioning amplifier connector.

  1. Reconnect the cooler (duct sensor) thermistor (rear room temperature sensor) connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER (Click here)