FRONT ACCELERATION SENSOR > INSPECTION |
| 1. INSPECT ACCELERATION SENSOR ASSEMBLY |
![]() |
Inspect the acceleration sensor LH.
Connect 3 dry cell batteries of 1.5 V in series.
Connect the positive (+) end of the batteries to terminal 3 (SGV) of the acceleration sensor and the negative (-) end of the batteries to terminal 2 (SGND). Then measure the voltage between terminal 1 (SGRR) and terminal 2 (SGND).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Sensor Condition | Specified Condition |
| 1 (SGRR) - 2 (SGND) | Sensor stationary | Approx. 2.0 to 2.5 V |
| Sensor is tilted | Change between approx. 0.9 to 2.3 V |
![]() |
Inspect the acceleration sensor RH.
Connect 3 dry cell batteries of 1.5 V in series.
Connect the positive (+) end of the batteries to terminal 3 (SHB) of the acceleration sensor and the negative (-) end of the batteries to terminal 2 (SHG). Then measure the voltage between terminal 1 (SGFL) and terminal 2 (SHG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Sensor Condition | Specified Condition |
| 1 (SGFL) - 2 (SHG) | Sensor stationary | Approx. 2.0 to 2.5 V |
| Sensor is tilted | Change between approx. 0.9 to 2.3 V |