ABSORBER CONTROL ACTUATOR > INSPECTION |
| 1. INSPECT ABSORBER CONTROL ACTUATOR |
![]() |
Inspect the absorber control actuator LH.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Sensor Condition | Specified Condition |
| 1 (FAL+) - 2 (FAL-) | Always | 6.4 to 7.2 Ω |
| 3 (FBL-) - 4 (FBL+) | Always | 6.4 to 7.2 Ω |
![]() |
Inspect the absorber control actuator RH.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Sensor Condition | Specified Condition |
| 1 (FAR+) - 2 (FAR-) | Always | 6.4 to 7.2 Ω |
| 3 (FBR-) - 4 (FBLR+) | Always | 6.4 to 7.2 Ω |