VANITY LIGHT > INSPECTION |
| 1. INSPECT VISOR ASSEMBLY LH |
![]() |
Connect the (+) lead from the battery to terminal 2 and the (-) lead to terminal 1.
Check that the vanity light comes on.
| Measurement Condition | Switch Condition | Specified Condition |
| Battery positive (+) → Terminal 2 Battery negative (-) → Terminal 1 | A | Vanity light comes on |
| B to A | Vanity light gradually becomes brighter | |
| B | Vanity light turns off |
| 2. INSPECT VISOR ASSEMBLY RH |
![]() |
Connect the (+) lead from the battery to terminal 2 and the (-) lead to terminal 1.
Check that the vanity light comes on.
| Measurement Condition | Switch Condition | Specified Condition |
| Battery positive (+) → Terminal 2 Battery negative (-) → Terminal 1 | A | Vanity light comes on |
| B to A | Vanity light gradually becomes brighter | |
| B | Vanity light turns off |