BLIND SPOT MONITOR MAIN SWITCH > INSPECTION |
| 1. INSPECT BLIND SPOT MONITOR MAIN SWITCH ASSEMBLY (WARNING CANCELING SWITCH ASSEMBLY) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 11 (B) - 8 (D) | Blind spot monitor main switch assembly (warning canceling switch assembly) on | Below 1 Ω |
| 11 (B) - 8 (D) | Blind spot monitor main switch assembly (warning canceling switch assembly) off | 10 kΩ or higher |
| *a | Component without harness connected (Blind Spot Monitor Main Switch Assembly (Warning Canceling Switch Assembly)) |
Check that the switch illuminates.
![]() |
Apply battery voltage to the blind spot monitor main switch assembly (warning canceling switch assembly) and check that the switch illuminates.
| Connection | Specified Condition |
| Battery positive (+) → Terminal 10 (ILL+) Battery negative (-) → Terminal 9 (ILL-) | Illuminates |
| *a | Component without harness connected (Blind Spot Monitor Main Switch Assembly (Warning Canceling Switch Assembly)) |
Check that the switch indicator operates.
![]() |
Apply battery voltage to the blind spot monitor main switch assembly (warning canceling switch assembly) and check the operation of the switch as shown in the table below.
| Connection | Switch Condition | Specified Condition |
| Battery positive (+) → Terminal 11 (B) Battery negative (-) → Terminal 12 (E) | Blind spot monitor main switch assembly (warning canceling switch assembly) on | Indicator Illuminates |
| *a | Component without harness connected (Blind Spot Monitor Main Switch Assembly (Warning Canceling Switch Assembly)) |