Home › Engine / Hybrid System › 3UR-FE ENGINE CONTROL › SFI SYSTEM

DTC    P2118    Throttle Actuator Control Motor Current Range / Performance

for Preparation Click here


DESCRIPTION

The ETCS (Electronic Throttle Control System) has a dedicated power supply circuit. The voltage (+BM) is monitored and when it is low (less than 4 V), the ECM determines that there is a malfunction in the ETCS and cuts off the current to the throttle actuator.
When the voltage becomes unstable, the ETCS itself becomes unstable. For this reason, when the voltage is low, the current to the throttle actuator is cut. If repairs are made and the system returns to normal, turn the ignition switch off. The ECM then allows the current to flow to the throttle actuator so that it can be restarted.

HINT:
The ETCS does not use a throttle cable.


A112629E21


DTC No.
DTC Detection Condition
Trouble Area
P2118
Open in ETCS power source (+BM) circuit
(1 trip detection logic)
  1. Open in ETCS power source circuit
  2. Battery
  3. Battery terminals
  4. ETCS fuse
  5. ECM

MONITOR DESCRIPTION

The ECM monitors the battery supply voltage applied to the throttle actuator.
When the power supply voltage (+BM) drops below 4 V for 0.8 seconds or more, the ECM interprets this as an open in the power supply circuit (+BM). The ECM illuminates the MIL and stores the DTC.
If the malfunction is not repaired successfully, the DTC is stored 5 seconds after the engine is next started.

FAIL-SAFE

When this DTC or other DTCs relating to ETCS (Electronic Throttle Control System) malfunctions are stored, the ECM enters fail-safe mode. During fail-safe mode, the ECM cuts the current to the throttle actuator, and the throttle valve is returned to a 7° throttle angle by the return spring. The ECM then adjusts the engine output by controlling the fuel injection (intermittent fuel-cut) and ignition timing, in accordance with the accelerator pedal opening angle, to allow the vehicle to continue at a minimal speed. If the accelerator pedal is depressed firmly and gently, the vehicle can be driven slowly.
Fail-safe mode continues until a pass condition is detected, and the ignition switch is then turned off.

WIRING DIAGRAM


A185022E01


INSPECTION PROCEDURE

HINT:
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.READ VALUE USING INTELLIGENT TESTER (+BM VOLTAGE)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the intelligent tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / +BM Voltage.

  1. Read the value displayed on the intelligent tester.
    Result 
    Result
    Proceed to
    Less than 11 V or more than 14 V
    A
    11 to 14 V
    B



B
CHECK FOR INTERMITTENT PROBLEMS (Click here)
A


2.INSPECT FUSE (ETCS)
A162288E01
  1. Remove the ETCS fuse from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    ETCS fuse
    Always
    Below 1 Ω



NG
CHECK FOR SHORTS IN ALL HARNESSES AND CONNECTORS CONNECTED TO FUSE AND REPLACE FUSE
OK


3.CHECK HARNESS AND CONNECTOR (ECM - ETCS FUSE, ETCS FUSE - BATTERY)
A162289E06
  1. Check the harness and connector between the ETCS fuse and ECM.

    1. Remove the ETCS fuse from the engine room relay block.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      ETCS fuse terminal 2 - D56-41 (+BM)
      Always
      Below 1 Ω
      ETCS fuse terminal 2 or D56-41 (+BM) - Body ground
      Always
      10 kΩ or higher

  1. Check the harness and connector between the ETCS fuse and positive battery cable.

    1. Remove the ETCS fuse from the engine room relay block.

    2. Disconnect the cable from the positive (+) battery terminal.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      Positive battery cable - ETCS fuse terminal 1
      Always
      Below 1 Ω
      Positive battery cable or ETCS fuse terminal 1 - Body ground
      Always
      10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.INSPECT ECM (+BM VOLTAGE)
A136305E63
  1. Disconnect the ECM connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    D56-41 (+BM) - D56-81 (E1)
    Always
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (TERMINAL E1 - BODY GROUND)
OK

REPLACE ECM (Click here)