Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM

DTC    B1423/23    Pressure Sensor Circuit

for Preparation Click here


DESCRIPTION

This DTC is output when refrigerant pressure on the high pressure side is extremely low (0.19 MPa [2.0 kgf/cm2, 28 psi] or less) or extremely high (3.14 MPa [32.0 kgf/cm2, 455 psi] or more). The air conditioning pressure sensor, which is installed on the pipe of the high pressure side to detect refrigerant pressure, outputs a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to pressure according to the sensor characteristics to control the compressor.

DTC Code
DTC Detection Condition
Trouble Area
B1423/23
  1. An open or short in the pressure sensor circuit
  2. Refrigerant pressure on the high pressure side is extremely low (or less) or extremely high.
  1. Air conditioning pressure sensor
  2. Harness or connector between air conditioning pressure sensor and air conditioning amplifier assembly
  3. Air conditioning amplifier assembly
  4. Air conditioning system (leaks, blocked)

WIRING DIAGRAM


E209344E01


INSPECTION PROCEDURE

1.CHECK REFRIGERANT PRESSURE


    E050573
  1. Install the manifold gauge set (Click here).

  1. Read the manifold gauge pressure when the following conditions are established.

    1. Prepare the vehicle in accordance with the chart below.
      Item
      Condition
      Engine speed
      1500 rpm
      Vehicle doors
      Fully open
      Temperature setting
      Lo
      Blower speed
      Hi
      A/C switch
      On
      R/F Switch
      Recirculation

    2. When the refrigerant volume is correct, the gauge reading indicates as follows:

      Standard:
      Refrigerant Pressure
      Specified Condition
      Low pressure side
      0.15 to 0.25 MPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)
      High pressure side
      1.37 to 1.57 MPa (14 to 16 kgf/cm2, 199 to 228 psi)

      HINT:
      Pressure varies in accordance with certain conditions (outside air temperature, sunlight and wind).



NG
Go to step 6
OK


2.READ VALUE USING INTELLIGENT TESTER (AIR CONDITIONING PRESSURE SENSOR)
  1. Use the Data List to check if the air conditioning pressure sensor is functioning properly.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Regulator Pressure Sensor
    Air conditioning pressure sensor /
    Min: -0.4566 MPaG
    Max: 3.2943 MPaG
    Actual regulator pressure for front seat is displayed
    -

    OK:
    The display is as specified in the normal condition.

    Result 
    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to Problem Symptoms Table)
    B
    OK (When troubleshooting according to the DTC output)
    C



B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
A


3.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
  1. Reconnect the A22 air conditioning pressure sensor connector.

  1. Remove the air conditioning amplifier assembly with its connectors still connected.



    E124471E87
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    H24-9 (PRE) - Body ground
    Ignition switch ON
    A/C switch off
    0.70 to 4.69 V

    HINT:
    If the measured voltage is not within the normal range, there may be a malfunction in the air conditioning amplifier assembly, air conditioning pressure sensor, or wire harness. It is also possible that the amount of refrigerant may not be appropriate.



NG
Go to step 5
OK


4.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)


  1. Measure the voltage when the following conditions are met.
    Measurement Condition 
    Item
    Condition
    Engine Speed
    2000 rpm
    Vehicle Doors
    Fully open
    Temperature Setting
    Lo
    Blower Speed
    Hi
    A/C Switch
    On
    R/F Switch
    Recirculation
    Interior Temperature
    25 to 35°C (77 to 95°F)

    NOTICE:
    1. If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.8 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.
    2. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the problem symptom may recur after a while.

    HINT:
    When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.



      E124471E87
    1. Measure the voltage according to the value(s) in the table below.

      Standard Voltage:
      Tester Connection
      Switch Condition
      Specified Condition
      H24-9 (PRE) - Body ground
      Ignition switch ON
      A/C switch on
      0.70 to 4.69 V

      Result 
      Result
      Proceed to
      OK (When troubleshooting according to the DTC)
      A
      OK (When troubleshooting according to Problem Symptoms Table)
      B
      NG
      C



B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
Go to step 5
A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)  

5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER)


    E127566E03
  1. Disconnect the A22 sensor connector.

  1. Disconnect the H24 amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A22-1 (-) - Body ground
    Always
    Below 1 Ω
    A22-2 (PR) - H24-9 (PRE)
    Always
    Below 1 Ω
    A22-3 (+) - H24-10 (S5-3)
    Always
    Below 1 Ω
    A22-2 (PR) - Body ground
    Always
    10 kΩ or higher
    A22-3 (+) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)  

6.CHECK FOR AIR CONDITIONING SYSTEM LEAK
  1. Install the manifold gauge set (Click here).

  1. Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.

  1. Evacuate the air conditioning system and check that vacuum can be maintained in it.

    OK:
    Vacuum can be maintained in the air conditioning system.

    HINT:
    If vacuum cannot be maintained in the air conditioning system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the air conditioning system.



NG
Go to step 9
OK


7.CHARGE REFRIGERANT
  1. Add an appropriate amount of refrigerant .


NEXT


8.RECHECK FOR DTC
  1. Recheck for the DTC when the following conditions are satisfied.

    Item
    Condition
    Vehicle Doors
    Fully open
    Temperature Setting
    Lo
    Blower Speed
    Hi
    A/C Switch
    On
    R/F Switch
    Recirculation
    Interior Temperature
    25 to 35°C (77 to 95°F) or higher
    Engine Speed
    2000 rpm

    NOTICE:
    If refrigerant pressure on the high pressure side becomes high, the DTC will be set. Therefore, it is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be set after the air conditioning operates for a while.

    HINT:
    When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

    NOTICE:
    If the DTC was stored due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leaks. The root cause of excessive refrigerant may be adding refrigerant when the level was insufficient. Therefore, identify and repair the area where refrigerant leaks from as necessary.

    OK:
    DTC B1423 is not output.



NG
Go to step 9
OK

END 

9.REPAIR AIR CONDITIONING SYSTEM LEAK
  1. Identify the area where refrigerant leaks .

  1. Repair the identified area of the air conditioning system.

  1. Evacuate the air conditioning system.


NEXT


10.CHARGE REFRIGERANT
  1. Use a refrigerant recovery unit to recover refrigerant.

  1. Evacuate the air conditioning system.

  1. Add an appropriate amount of refrigerant .

    HINT:
    If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system may freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant, properly evacuate the system, add an appropriate amount of refrigerant, and check for the DTC.


NEXT


11.RECHECK FOR DTC
  1. Recheck for the DTC when the following conditions are satisfied.

    Item
    Condition
    Vehicle Doors
    Fully open
    Temperature Setting
    Lo
    Blower Speed
    Hi
    A/C Switch
    On
    R/F Switch
    Recirculation
    Interior Temperature
    25 to 35°C (77 to 95°F) or higher
    Engine Speed
    2000 rpm

    NOTICE:
    If refrigerant pressure on the high pressure side becomes high, the DTC will be set. Therefore, it is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be set after the air conditioning operates for a while.

    HINT:
    1. When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
    2. If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system may freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant, properly evacuate the system, add an appropriate amount of refrigerant, and check for the DTC. If the DTC is not output after this work, it indicates that the cooler dryer in the condenser is not able to absorb moisture in the refrigerant cycle. In this case, to complete the repair it is necessary to replace the cooler dryer.

    OK:
    DTC B1423 is not output.



NG
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
OK

END