Home › Drivetrain · AB60F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM

DTC    P2759    Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)

for Preparation Click here


DESCRIPTION

The amount of current flow to the solenoid is controlled by the duty ratio* of the ECM output signal. During the lock-up operation, if the duty ratio increases, the lock-up hydraulic pressure increases.

C161168E03

*: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF time (A + B).
Duty Ratio (%) = A / (A + B) x 100

DTC Code
DTC Detection Condition
Trouble Area
P2759
Open or short is detected in the shift solenoid valve SLU circuit for 1 second or more while driving (1 trip detection logic).
  1. Open or short in shift solenoid valve SLU circuit
  2. Shift solenoid valve SLU
  3. ECM
Reference: Inspect using an oscilloscope.
Check the waveform of the ECM connector.
C162560E03

Standard:
Terminal No. (Symbol)
Tool Setting
Condition
Specified Condition
D56-10 (SLU+) - D56-11 (SLU-)
5 V/DIV., 1 msec./DIV.
5th gear (lock-up) or 6th gear (lock-up)
Refer to illustration


MONITOR DESCRIPTION

When an open or short in a shift solenoid valve SLU circuit is detected, the ECM determines that there is a malfunction. The ECM will illuminate the MIL and store the DTC.

WIRING DIAGRAM


C219459E04


INSPECTION PROCEDURE

1.INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)


    C214326E40
  1. Disconnect the D41 No. 1 transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    12 (SLU+) - 4 (SLU-)
    20°C (68°F)
    5.0 to 5.6 Ω
    12 (SLU+) - Body ground
    Always
    10 kΩ or higher
    4 (SLU-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (No. 1 Transmission Wire)



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
C219456E14
  1. Disconnect the D56 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    D56-10 (SLU+) - D56-11 (SLU-)
    20°C (68°F)
    5.0 to 5.6 Ω
    D56-10 (SLU+) - Body ground
    Always
    10 kΩ or higher
    D56-11 (SLU-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

3.INSPECT SHIFT SOLENOID VALVE SLU
C209928E07
  1. Remove the shift solenoid valve SLU.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 2
    2. Battery negative (-) → Terminal 1
    Valve moves and makes an operating noise

Text in Illustration 
*a
Component without harness connected
(Shift Solenoid Valve SLU)


NG
REPLACE SHIFT SOLENOID VALVE SLU
OK

REPAIR OR REPLACE NO. 1 TRANSMISSION WIRE (Click here)