DTC P0748 Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1) |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0748 | The ECM checks for an open or short in the shift solenoid valve SL1 circuit while driving and shifting between 4th and 5th gear (1 trip detection logic) Output signal duty equals to 100%
|
|

| Item | Content |
| Terminal No. (Symbol) | D56-14 (SL1+) - D56-15 (SL1-) |
| Tool setting | 5 V/DIV., 1 msec./DIV. |
| Condition | 5th or 6th gear |

| ECM gear shift command | 1st | 2nd | 3rd | 4th | 5th | 6th |
| Shift solenoid valve SL1 | OFF | OFF | OFF | OFF | ON | ON |
| 1.INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL1) |
![]() |
Disconnect the D41 No. 1 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 11 (SL1+) - 3 (SL1-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 11 (SL1+) - Body ground | Always | 10 kΩ or higher |
| 3 (SL1-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM) |
![]() |
Disconnect the D56 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D56-14 (SL1+) - D56-15 (SL1-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| D56-14 (SL1+) - Body ground | Always | 10 kΩ or higher |
| D56-15 (SL1-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SL1 |
![]() |
Remove the shift solenoid valve SL1.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect the battery positive (+) lead with a 21 W bulb to terminal 1 and the negative (-) lead to terminal 2 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
|
| ||||
| OK | ||
| ||