1. INSTALL COOLER CONDENSER ASSEMBLY


E179121
  1. Install the cooler condenser with the 2 bolts, as shown in the illustration.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }

    NOTICE:
    Do not damage the cooler condenser when installing the condenser.

    HINT:
    If a new cooler condenser is installed, add compressor oil to the condenser as follows.

    Capacity:
    Add 40 cc (1.35 fl. oz.)

    Compressor oil:
    ND-OIL8 or equivalent.



2. CONNECT AIR CONDITIONING TUBE ASSEMBLY


I104360
  1. Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring on to the air conditioning tube.

  1. Connect the air conditioning tube on to the cooler condenser with the 2 bolts.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



3. CONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE


E179119
  1. Remove the attached vinyl tape from the hose and the connecting part of the cooler condenser.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the hose joint.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring on to the discharge hose.

  1. Connect the discharge hose on to the cooler condenser with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



4. INSTALL RADIATOR ASSEMBLY
  1. Install the radiator assembly (Click here).



5. CHARGE REFRIGERANT



I100449E02

NOTICE:
Charge refrigerant in accordance with the equipment manual.

  1. Perform vacuum purging using a vacuum pump.

  1. Charge refrigerant HFC-134a (R134a).

    SST
    09985-20010   (09985-02010, 09985-02050, 09985-02060, 09985-02070, 09985-02080, 09985-02090, 09985-02110, 09985-02130, 09985-02140, 09985-02150)

    Standard:
    Cool Box
    Refrigerant Charging Amount
    w/ Cool Box
    1080 to 1140 g (38.1 to 40.2 oz.)
    w/o Cool Box
    920 to 980 g (32.4 to 34.6 oz.)

    NOTICE:
    Do not start the engine before charging it with refrigerant as the cooler compressor does not work properly without sufficient refrigerant. This could cause the compressor to overheat.

    HINT:

    1. The relationship between the refrigerant charge amount and the pressure is as follows.


      I103968E01

    2. High Charge Range:
      If the refrigerant is overcharged, the pressure rises on the high-pressure side. High-pressure cut off frequently occurs. This causes insufficient cooling performance and also insufficient compressor lubrication.
    3. Low Charge Range:
      A shortage of refrigerant causes insufficient cooling performance and low circulation of refrigerant oil, which shortens the compressor life. Operation with insufficient coolant raises the refrigerant temperature and causes heat deterioration of the rubber seals and hoses. Cracking and subsequent refrigerant leakage may occur.


    1. Install the caps onto the service valves on the refrigerant line.



6. WARM UP ENGINE

NOTICE:
Warm up the engine at less than 2000 rpm for 1 minute or more after charging it with refrigerant.



7. INSPECT FOR REFRIGERANT LEAK
  1. After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.

  1. Perform the operation as follows:

    1. Stop the engine.
    2. Secure good ventilation (the halogen leak detector may react to volatile gases other than refrigerant, such as evaporated gasoline or exhaust gas).
    3. Repeat the test 2 or 3 times.
    4. Make sure that some refrigerant remains in the refrigeration system.
      When the compressor is off: approximately 392 to 588 kPa (4 to 6 kgf/cm2, 57 to 85 psi)

    HINT:
    It is impossible for the above pressure to be maintained if there is leakage.



    I042222E14
  1. Using the halogen leak detector, check the refrigerant line, especially at the connection points, for leakage.

  1. If no gas leakage is detected from the drain hose, remove the blower motor from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.

  1. Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.