Home › Vehicle Exterior › EXTERIOR PANELS / TRIM › ROOF DRIP SIDE FINISH MOULDING

ROOF DRIP SIDE FINISH MOULDING > INSTALLATION

for Preparation Click here



1. INSTALL ROOF DRIP SIDE FINISH MOULDING CLIP


B191711E01

NOTICE:
Only follow this procedure when replacing the clips.

  1. Remove the tape that remains on the moulding surface of the vehicle body, and then clean the surface with a non-residue solvent.

  1. Using an infrared light, heat the clip installation surface on the vehicle body and roof drip side finish moulding.

    Standard:
    Area
    Temperature
    Vehicle Body
    40 to 60°C (104 to 140°F)
    Roof Drip Side Finish Moulding
    20 to 30°C (68 to 86°F)

    NOTICE:
    Do not excessively heat the vehicle body or roof drip side finish moulding.

  1. Install new clips in the positions shown in the illustration. Press in the clips by hand.

    Standard:
    Area
    Measurement
    a
    4.7 mm (0.185 in.)
    b
    5.1 mm (0.201 in.)
    c
    4.7 mm (0.185 in.)
    d
    5.0 mm (0.197 in.)

    NOTICE:
    After pressing in the clips, wait 30 minutes or more before installing the roof drip side finish moulding.

    HINT:
    1. Minimum hardening time: 30 minutes
    2. Time needed for complete hardening: 24 hours



2. INSTALL ROOF DRIP SIDE FINISH MOULDING


    B191710
  1. Attach the 2 clips to install the roof drip side finish moulding.

  1. Remove the protective tape.