AIR CONDITIONING SYSTEM > CHECK MODE PROCEDURE |
| PANEL DIAGNOSIS (INDICATOR CHECK) |
Turn the ignition switch off.
![]() |
Press and hold the A/C control AUTO switch and Recirculation/Fresh switch simultaneously, and turn the ignition switch to ON. Continue holding the 2 switches until the panel diagnosis mode begins.
![]() ![]() |
Check that all indicators and the display area are turned on and off 4 times in succession at 1 second intervals.
Press the OFF switch to terminate the panel diagnosis.
| PANEL DIAGNOSIS (SENSOR CHECK) |
Perform the indicator check.
Press the REC/FRS switch to enter actuator check mode.
After the actuator check is completed, press the AUTO switch to enter sensor check mode.
![]() |
Check the sensor check results displayed on the set temperature display.
| Result | Code Display |
| Present malfunction | Blinks |
| Past malfunction | Blinks |
When any sensor check codes are displayed, refer to the DTC Chart (Click here).
Press the OFF switch to terminate the panel diagnosis.
| PANEL DIAGNOSIS (CLEAR SENSOR CHECK CODE) |
Inspect and repair or replace the malfunctioning parts.
![]() |
Clear the sensor check codes.
While pressing the Fr DEF switch during sensor check mode, press the Rr DEF switch.
Perform the sensor check and confirm that normal code 00 is displayed.
| PANEL DIAGNOSIS (ACTUATOR CHECK) |
![]() |
Start the engine and warm it up.
Perform the indicator check.
When the sensor check is started after the indicator check, press the REC/FRS switch to start the actuator check.
Check the temperature and blower levels by hand at each step while the actuator check proceeds from step 0 to 9 at 1 second intervals (continuous operation).

To display step numbers one by one manually, press the Fr DEF switch to activate the step operation. The step number changes each time the Fr DEF switch is pressed.
Press the OFF switch to terminate the panel diagnosis.
| Step No. (Front display) | Blower Level | Front Air Mix Damper | Air Flow Vent | Air Inlet Damper | Cool Air Bypass | Compressor | Rear Air Mix Damper | Rear Air Flow Vent | Rear Blower Level |
| 0 | 0 | 0% (MAX COLD) | FACE | FRESH | 0% | off | 0 | Rr FACE | 0 |
| 1 | 1 | 0% (MAX COLD) | FACE | FRESH | 0% | off | 0 | Rr FACE | 1 |
| 2 | 17 | 0% (MAX COLD) | FACE | RECIRCULATION / FRESH | 0% | on | 0 | Rr FACE | 17 |
| 3 | 17 | 0% (MAX COLD) | FACE | RECIRCULATION | 100% | on | 0 | Rr FACE | 17 |
| 4 | 17 | 50% | BI-LEVEL | RECIRCULATION | 100% | on | 50 | Rr BI-LEVEL | 17 |
| 5 | 17 | 50% | BI-LEVEL | RECIRCULATION | 100% | on | 50 | Rr BI-LEVEL | 17 |
| 6 | 17 | 50% | FOOT | FRESH | 100% | on | 50 | Rr FOOT | 17 |
| 7 | 17 | 100% (MAX HOT) | FOOT | FRESH | 100% | on | 100 | Rr FOOT | 17 |
| 8 | 17 | 100% (MAX HOT) | FOOT/DEF | FRESH | 100% | on | 100 | Rr FOOT | 17 |
| 9 | 31 | 100% (MAX HOT) | DEF | FRESH | 100% | on | 100 | Rr FOOT | 31 |