Home › General › SPECIFICATIONS › 3UR-FE STARTING

3UR-FE STARTING > SERVICE DATA



Starter assembly
Specified current: 150 A or less at 11.5 V
Starter armature assembly
Standard resistance:
Segment - Segment: Below 1 Ω
Segment - Coil core: 10 kΩ or higher
Standard diameter: 29.0 mm (1.14 in.)
Minimum diameter: 28.0 mm (1.10 in.)
Standard undercut depth: 0.4 mm (0.0157 in.)
Minimum undercut depth: 0.2 mm (0.00787 in.)
Maximum circle runout: 0.05 mm (0.00197 in.)
Brush length
Standard brush length: 14.4 mm (0.567 in.)
Minimum brush length: 9.0 mm (0.354 in.)
Starter brush holder assembly
Standard spring installed load:
22 to 27 N (2 to 3 kgf, 5.0 to 6.1 lbf)
Minimum spring installed load:
14 N (1 kgf, 3.1 lbf)
Magnet starter switch assembly
Standard resistance:
Terminal 50 - Terminal C: Below 1 Ω
Standard resistance:
Terminal 50 - Switch body: Below 2 Ω
Starter relay
3 - 5: 10 kΩ or higher (When battery voltage is not applied to terminals 1 and 2)
3 - 5: Below 1 Ω (When battery voltage is applied to terminals 1 and 2)
ACC relay
(Main body ECU)
DD-47 - DD-8: 10 kΩ or higher (When battery voltage is not applied between DD-45 and DD-62)
DD-47 - DD-8: Below 1 Ω (When battery voltage is applied between DD-45 and DD-62)
ACC cut relay
3 - 4: Below 1 Ω (When battery voltage is not applied to terminals 1 and 2)
3 - 4: 10 kΩ or higher (When battery voltage is applied to terminals 1 and 2)
3 - 5: 10 kΩ or higher (When battery voltage is not applied to terminals 1 and 2)
3 - 5: Below 1 Ω (When battery voltage is applied to terminals 1 and 2)