DESCRIPTION

The blower with fan motor sub-assembly is operated by signals from the air conditioning amplifier assembly. Blower with fan motor sub-assembly speed signals are transmitted by changes in the duty ratio.
Duty Ratio:
E132503E04
The duty ratio is the ratio of the blower with fan motor sub-assembly ON time (B) to the total of the blower with fan motor sub-assembly OFF and ON time (A + B).
The air conditioning amplifier assembly controls the blower with fan motor sub-assembly speed.

WIRING DIAGRAM


E182387E02


INSPECTION PROCEDURE

1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (BLOWER MOTOR)
  1. Select the Active Test, use the intelligent tester to generate a control command, and then check that the blower with fan motor sub-assembly operates.

    Air Conditioner 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower motor
    Min.: 0, Max.: 31
    -

    OK:
    Blower motor operates and blower motor speed level changes.

    Result 
    Result
    Proceed to
    OK (Blower motor operates normally)
    A
    NG (Blower motor does not operate)
    B
    NG (Blower motor operates but does not change speed)
    C



B
Go to step 2

C
Go to step 5
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.INSPECT FUSE (HTR)


    E161570E05
  1. Remove the HTR fuse from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    HTR fuse
    Always
    Below 1 Ω



NG
REPLACE FUSE
OK


3.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BATTERY AND BODY GROUND)
E146411E03
  1. Disconnect the H41 motor connector.

  1. Measure the resistance and voltage according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    H41-3 (GND) - Body ground
    Always
    Below 1 Ω

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    H41-1 (+B) - Body ground
    Always
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BLOWER MOTOR)
E161571E02
  1. Disconnect the H24 amplifier connector.

  1. Disconnect the H41 motor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    H24-23 (BLW) - H41-2 (SI)
    Always
    Below 1 Ω
    H24-23 (BLW) or H41-2 (SI) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK BLOWER WITH FAN MOTOR SUB-ASSEMBLY (S1 VOLTAGE)
E124470E56
  1. Disconnect the H24 amplifier connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    H24-23 (BLW) - Body ground
    Ignition switch ON
    4.5 to 5.5 V



NG
REPLACE BLOWER WITH FAN MOTOR SUB-ASSEMBLY (Click here)
OK


6.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (BLW VOLTAGE)
E127572E07
  1. Remove the air conditioning amplifier assembly with its connectors still connected (Click here).

  1. Check the waveform of the air conditioning amplifier connector.
    Measurement Condition 
    Item
    Content
    Terminal No. (Symbol)
    H24-23 (BLW) - H24-14 (GND)
    Tool Setting
    1 V/DIV, 500 μsec./DIV.
    Condition
    Ignition switch ON
    Blower switch lo

    HINT:
    Waveform varies with the blower level.



NG
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)