METER / GAUGE SYSTEM > Meter Illumination is Always Dark |

| 1.CHECK ILLUMINATION FUNCTION |
Check the illumination function.
| Result | Proceed to |
| Accessory meter illumination is always dark | A |
| Combination meter illumination is always dark | B |
|
| ||||
| A | |
| 2.INSPECT FUSE (PANEL) |
![]() |
Remove the PANEL fuse from the cowl side junction block LH.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| PANEL fuse | Always | Below 1 Ω |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (ACCESSORY METER - BATTERY) |
![]() |
Disconnect the I22 accessory meter connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| I22-21 (ILL+) - Body ground | Light control switch ON | 11 to 14 V |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (COMBINATION METER - ACCESSORY METER AND BODY GROUND) |
![]() |
Disconnect the H37 combination meter connector.
Disconnect the I22 accessory meter connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| H37-37 (ILL-) - I22-20 (ILL-) | Always | Below 1 Ω |
| H37-37 (ILL-) - Body ground | Always | 10 kΩ or higher |
| H37-40 (E1) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 5.REPLACE ACCESSORY METER ASSEMBLY |
Temporarily replace the accessory meter with a new or normally functioning one (Click here).
| NEXT | |
| 6.CHECK ACCESSORY METER ASSEMBLY (OPERATION) |
Check the accessory meter operation.
|
| ||||
| OK | ||
| ||