Home › Engine / Hybrid System › 3UR-FE ENGINE CONTROL › ECM

ECM > INSTALLATION

for Preparation Click here



1. INSTALL GASKET
  1. Clean the ECM seal's surface with non-residue solvent.

  1. Attach a new gasket to the ECM.



2. INSTALL ECM


    A155993
  1. Install the ECM with the 4 bolts.

    Torque:
    8.0 N*m{ 82 kgf*cm , 71 in.*lbf }

    NOTICE:
    1. Make sure that the gasket is not folded or caught on any area on the surrounding part.
    2. Make sure that there is no foreign matter caught between the gasket and surrounding part.
    3. Do not damage the gasket.



    A160064
  1. Connect the 2 ECM connectors and push each lock lever down to lock the ECM connectors.

    NOTICE:
    1. Make sure that the lock lever is raised 90° before connecting the ECM connectors. Failure to do this may cause the lock lever and terminals to break.
    2. Do not twist the wire harness when connecting the ECM connectors.



3. CONNECT CONNECTOR HOLDER BLOCK


    A155992
  1. Connect the connector holder block with the 3 bolts.

    Torque:
    7.3 N*m{ 74 kgf*cm , 65 in.*lbf }



4. INSTALL AIR CLEANER ASSEMBLY


    A183246E01
  1. Attach grommet to air cleaner before mounting the air cleaner.

  1. Insert the air cleaner into the fender apron hole, and fully insert pin to grommet.



    A183242
  1. Install the air cleaner with the 2 bolts.

    Torque:
    5.0 N*m{ 51 kgf*cm , 44 in.*lbf }

  1. Connect the connector and install the clamp and wire harness.

  1. Connect the air cleaner hose and tighten the clamp.

    Torque:
    4.0 N*m{ 41 kgf*cm , 35 in.*lbf }



5. PERFORM INITIALIZATION
  1. Perform initialization procedures (Click here).