Home › General › SPECIFICATIONS › 3UR-FE EMISSION CONTROL

3UR-FE EMISSION CONTROL > SERVICE DATA



Pressure sensor
(w/ Secondary air injection system)
D37-2 (VC) - D37-4 (E2)
(for Bank 1)
Ignition switch ON
4.75 to 5.25 V
D38-2 (VC2) - D38-4 (E22)
(for Bank 2)
Electric air control valve
(w/ Secondary air injection system)
1 - 5
20°C (68°F)
4.5 to 5.5 Ω
1 - Body ground
5 - Body ground
Always
1 MΩ or higher
Purge VSV
1 - 2
20°C (68°F)
23 to 26 Ω
1 - VSV body ground
2 - VSV body ground
Always
10 kΩ or higher