Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM

DTC    B1417/17    Rear Evaporator Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The rear evaporator temperature sensor is installed on the evaporator in the rear air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and to control the rear air conditioning. It sends signals to the air conditioning amplifier assembly. The signals change in accordance with the resistance of the rear evaporator temperature sensor. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier assembly applies a voltage (5 V) to the rear evaporator temperature sensor and reads voltage changes as changes in the resistance of the rear evaporator temperature sensor. This sensor is used for frost prevention.

DTC Code
DTC Detection Condition
Trouble Area
B1417/17
An open or short in rear evaporator temperature sensor circuit.
  1. No. 2 air conditioning harness assembly (rear evaporator temperature sensor)
  2. Harness or connector between No. 2 air conditioning harness assembly and air conditioning amplifier assembly
  3. Air conditioning amplifier assembly

WIRING DIAGRAM


E160576E07


INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (REAR EVAPORATOR TEMPERATURE SENSOR)
  1. Use the Data List to check if the rear evaporator temperature sensor is functioning properly.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temp Sens (Rear)
    Rear evaporator temperature sensor /
    Min.: -29.7°C (-21.46°F)
    Max.: 59.25°C (138.65°F)
    Actual rear evaporator temperature is displayed
    Open in the circuit: -29.7°C (-21.46°F)
    Short in the circuit: 59.25°C (138.65°F)

    OK:
    The display is as specified in the normal condition.

    Result 
    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to Problem Symptoms Table)
    B
    OK (When troubleshooting according to the DTC output)
    C



B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
A


2.INSPECT REAR EVAPORATOR TEMPERATURE SENSOR


    E127592E09
  1. Remove the No. 2 air conditioning harness assembly (rear evaporator temperature sensor) .

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    7 (-) - 8 (+)
    -10°C (14°F)
    7.30 to 9.10 kΩ
    -5°C (23°F)
    5.65 to 6.95 kΩ
    0°C (32°F)
    4.40 to 5.35 kΩ
    5°C (41°F)
    3.40 to 4.15 kΩ
    10°C (50°F)
    2.70 to 3.25 kΩ
    15°C (59°F)
    2.14 to 2.58 kΩ
    20°C (68°F)
    1.71 to 2.05 kΩ
    25°C (77°F)
    1.38 to 1.64 kΩ
    30°C (86°F)
    1.11 to 1.32 kΩ

    HINT:
    As the temperature increases, the resistance decreases (see the graph).

    NOTICE:
    1. Touching the thermistor even slightly may change the resistance value. Be sure to hold the connector of the thermistor.
    2. When measuring, the thermistor temperature must be the same as the ambient temperature.



NG
REPLACE NO. 2 AIR CONDITIONING HARNESS ASSEMBLY
OK


3.CHECK HARNESS AND CONNECTOR (NO. 2 AIR CONDITIONING HARNESS - AIR CONDITIONING AMPLIFIER)


    E127593E05
  1. Disconnect the P9 No. 2 air conditioning harness assembly connector.

  1. Disconnect the H67 amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P9-8 (+) - H67-4 (TEC)
    Always
    Below 1 Ω
    P9-7 (-) - H67-19 (SGND)
    Always
    Below 1 Ω
    P9-8 (+) or H67-4 (TEC) - Body ground
    Always
    10 kΩ or higher
    P9-7 (-) or H67-19 (SGND) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)