Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM

AIR CONDITIONING SYSTEM > Rear Blower Motor Circuit

for Preparation Click here


DESCRIPTION

The rear blower with fan motor sub-assembly is operated by signals from the air conditioning amplifier assembly. Rear blower with fan motor sub-assembly speed signals are transmitted in accordance with changes in the duty ratio.
Duty Ratio:
E132503E04
The duty ratio is the ratio of the rear blower with fan motor sub-assembly ON time (B) to the total of the rear blower with fan motor sub-assembly OFF and ON time (A + B).
The blower motor control controls the rear blower with fan motor sub-assembly speed.

WIRING DIAGRAM


E161574E02


INSPECTION PROCEDURE

1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (REAR BLOWER MOTOR)
  1. Select the Active Test, use the intelligent tester to generate a control command, and then check that the rear blower motor operates.

    Air Conditioner 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Rear Blower Motor
    Rear blower motor
    Min.: 0, Max.: 31
    -
    Result 
    Result
    Proceed to
    Rear blower motor operates normally
    A
    Rear blower motor does not operate
    B
    Rear blower motor operates but does not change speed
    C



B
Go to step 2

C
Go to step 6
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.INSPECT FUSE (RR HTR)


    E161570E06
  1. Remove the RR HTR fuse from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    RR HTR fuse
    Always
    Below 1 Ω



NG
REPLACE FUSE
OK


3.INSPECT REAR BLOWER WITH FAN MOTOR SUB-ASSEMBLY


    E162302E02
  1. Remove the rear blower with fan motor sub-assembly (Click here).

  1. Check the rear blower motor.

    OK:
    Tester Connection
    Specified Condition
    Battery positive (+) → 2 (B)
    Battery negative (-) → 1 (L)
    The rear blower motor operates smoothly.



NG
REPLACE REAR BLOWER WITH FAN MOTOR SUB-ASSEMBLY (Click here)
OK


4.CHECK HARNESS AND CONNECTOR (REAR BLOWER MOTOR - REAR BLOWER MOTOR CONTROL AND BODY GROUND)


    E161576E02
  1. Disconnect the P10 motor connector.

  1. Disconnect the P11 control connector.

  1. Measure the resistance according the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P10-2 (B) - P11-2 (VM)
    Always
    Below 1 Ω
    P10-1 (L) - Body ground
    Always
    Below 1 Ω
    P10-2 (B) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK HARNESS AND CONNECTOR (REAR BLOWER MOTOR CONTROL - BATTERY AND BODY GROUND)


    E161575E02
  1. Disconnect the P11 control connector.

  1. Measure the resistance and voltage according the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P11-6 (GND) - Body ground
    Always
    Below 1 Ω

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    P11-1 (+B) - Body ground
    Ignition switch ON
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - AIR CONDITIONING AMPLIFIER)


    E161577E03
  1. Disconnect the P11 control connector.

  1. Disconnect the H67 amplifier connector.

  1. Measure the resistance according the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P11-3 (SI)- H67-22 (BLWH)
    Always
    Below 1 Ω
    P11-3 (SI) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


7.CHECK BLOWER MOTOR CONTROL


    E127605E03
  1. Disconnect the H67 amplifier connector.

  1. Measure the voltage according the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    H67-22 (BLWH) - H67-20 (RGND)
    Ignition switch ON
    Rear blower motor switch off
    4.5 to 7 V



NG
REPLACE BLOWER MOTOR CONTROL (Click here)
OK


8.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY


    E127604E15
  1. Remove the air conditioning amplifier assembly with its connectors still connected (Click here).

  1. Check the waveform of the air conditioning amplifier connector.
    Measurement Condition 
    Item
    Content
    Terminal No. (Symbol)
    H67-22 (BLWH) - H67-20 (RGND)
    Tool Setting
    1 V/DIV., 500 μsec./DIV.
    Condition
    Ignition switch ON
    Blower switch lo



NG
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
OK

REPLACE REAR BLOWER WITH FAN MOTOR SUB-ASSEMBLY (Click here)