Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    B1412/12    Ambient Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The ambient temperature sensor is installed in front of the condenser to detect the ambient temperature which is used to control the air conditioner "AUTO" mode. This sensor is connected to the A/C amplifier and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the A/C amplifier. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The A/C amplifier applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes.

DTC No.
DTC Detection Condition
Trouble Area
B1412/12
Open or short in ambient temperature sensor circuit
  1. Ambient temperature sensor
  2. Harness or connector between ambient temperature sensor and A/C amplifier
  3. A/C amplifier

WIRING DIAGRAM


I008282E17


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the ignition switch to the ON position and turn Techstream on.

  1. Select the item below in the Data List, and read the display on Techstream.

    Data List / Air Conditioner: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temp Sensor
    Ambient temperature sensor / min: -23.3°C (-9.94°F), max: 65.95°C (150.71°F)
    Actual ambient temperature is displayed
    -

    OK:
    The display is as specified in the normal condition column.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE A/C AMPLIFIER
A


2.INSPECT AMBIENT TEMPERATURE SENSOR


    E118395E14
  1. Remove the ambient temperature sensor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A1-1 - A1-2
    10°C (50°F)
    3.00 to 3.73 kΩ
    A1-1 - A1-2
    15°C (59°F)
    2.45 to 2.88 kΩ
    A1-1 - A1-2
    20°C (68°F)
    1.95 to 2.30 kΩ
    A1-1 - A1-2
    25°C (77°F)
    1.60 to 1.80 kΩ
    A1-1 - A1-2
    30°C (86°F)
    1.28 to 1.47 kΩ
    A1-1 - A1-2
    35°C (95°F)
    1.00 to 1.22 kΩ
    A1-1 - A1-2
    40°C (104°F)
    0.80 to 1.00 kΩ
    A1-1 - A1-2
    45°C (113°F)
    0.65 to 0.85 kΩ
    A1-1 - A1-2
    50°C (122°F)
    0.50 to 0.70 kΩ
    A1-1 - A1-2
    55°C (131°F)
    0.44 to 0.60 kΩ
    A1-1 - A1-2
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE AMBIENT TEMPERATURE SENSOR
OK


3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - A/C AMPLIFIER)


    E124473E06
  1. Disconnect the ambient temperature sensor connector.



    E143742E26
  1. Disconnect the A/C amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A1-2 - A9-32 (TAM)
    Always
    Below 1 Ω
    A1-1 - A9-24 (SG-6)
    Always
    Below 1 Ω
    A9-32 (TAM) - Body ground
    Always
    10 kΩ or higher
    A9-24 (SG-6) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE A/C AMPLIFIER