Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    B1417/17    Rear Evaporator Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The rear evaporator temperature sensor is installed on the rear evaporator. It detects the rear evaporator temperature. The sensor sends a signal to the A/C amplifier. The resistance of the rear evaporator temperature sensor changes in accordance with the rear evaporator temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The A/C amplifier applies voltage (5 V) to the rear evaporator temperature sensor and reads voltage changes as the resistance of the rear evaporator temperature sensor changes.

DTC No.
DTC Detection Condition
Trouble Area
B1417/17
Open or short in rear evaporator temperature sensor circuit
  1. Rear evaporator temperature sensor
  2. Harness or connector between rear evaporator temperature sensor and A/C amplifier
  3. A/C amplifier

WIRING DIAGRAM


I008282E19


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the ignition switch to the ON position and turn Techstream on.

  1. Select the item below in the Data List, and read the display on Techstream.

    Data List / Air Conditioner: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temp Sens (Rear)
    Rear evaporator temperature sensor / min: -29.7°C (-21.46°F), max: 59.55°C (139.19°F)
    Actual rear evaporator temperature is displayed
    -

    OK:
    The display is as specified in the normal condition column.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE A/C AMPLIFIER
A


2.INSPECT REAR EVAPORATOR TEMPERATURE SENSOR


    E112577E07
  1. Remove the rear evaporator temperature sensor.



  1. Measure the resistance according to the value(s) in the table below.


    I040629E04

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A26-1 - A26-2
    -10°C (14°F)
    7.40 to 9.20 kΩ
    A26-1 - A26-2
    -5°C (23°F)
    5.65 to 7.00 kΩ
    A26-1 - A26-2
    0°C (32°F)
    4.35 to 5.40 kΩ
    A26-1 - A26-2
    5°C (41°F)
    3.40 to 4.20 kΩ
    A26-1 - A26-2
    10°C (50°F)
    2.68 to 3.30 kΩ
    A26-1 - A26-2
    15°C (59°F)
    2.10 to 2.60 kΩ
    A26-1 - A26-2
    20°C (68°F)
    1.66 to 2.10 kΩ
    A26-1 - A26-2
    25°C (77°F)
    1.32 to 1.66 kΩ
    A26-1 - A26-2
    30°C (86°F)
    1.05 to 1.35 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the rear evaporator temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE REAR EVAPORATOR TEMPERATURE SENSOR
OK


3.CHECK HARNESS AND CONNECTOR (REAR EVAPORATOR TEMPERATURE SENSOR - A/C AMPLIFIER)


    E124472E10
  1. Disconnect the rear evaporator temperature sensor connector.



    E141047E07
  1. Disconnect the A/C amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A26-2 - A10-17 (TEC)
    Always
    Below 1 Ω
    A26-1 - A10-13 (SG)
    Always
    Below 1 Ω
    A10-17 (TEC) - Body ground
    Always
    10 kΩ or higher
    A10-13 (SG) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE A/C AMPLIFIER