Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    B1413/13    Evaporator Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The evaporator temperature sensor (A/C thermistor) is installed on the evaporator in the air conditioning unit. It detects the temperature of the cooled air that has passed through the evaporator and its signal is used to control the air conditioning. It sends a signal to the A/C amplifier. The resistance of the evaporator temperature sensor (A/C thermistor) changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The A/C amplifier applies voltage (5 V) to the evaporator temperature sensor (A/C thermistor) and reads voltage changes as the resistance of the evaporator temperature sensor (A/C thermistor) changes. This sensor is used to prevent the evaporator from freezing.

DTC No.
DTC Detection Condition
Trouble Area
B1413/13
Open or short in evaporator temperature sensor circuit
  1. Evaporator temperature sensor
  2. Harness or connector between evaporator temperature sensor and A/C amplifier
  3. A/C amplifier

WIRING DIAGRAM


I035354E03


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the ignition switch to the ON position and turn Techstream on.

  1. Select the item below in the Data List, and read the display on Techstream.

    Data List / Air Conditioner: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Evaporator Temp Sensor
    Evaporator thermistor / min.: -29.7°C (-21.46°F), max.: 59.55°C (139.19°F)
    Actual evaporator temperature is displayed
    -

    OK:
    The display is as specified in the normal condition column.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE A/C AMPLIFIER
A


2.INSPECT EVAPORATOR TEMPERATURE SENSOR


    E148014E02
  1. Disconnect the connector from the evaporator temperature sensor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A12-1 - A12-2
    -10°C (14°F)
    7.30 to 9.10 kΩ
    A12-1 - A12-2
    -5°C (23°F)
    5.65 to 6.95 kΩ
    A12-1 - A12-2
    0°C (32°F)
    4.40 to 5.35 kΩ
    A12-1 - A12-2
    5°C (41°F)
    3.40 to 4.15 kΩ
    A12-1 - A12-2
    10°C (50°F)
    2.70 to 3.25 kΩ
    A12-1 - A12-2
    15°C (59°F)
    2.14 to 2.58 kΩ
    A12-1 - A12-2
    20°C (68°F)
    1.71 to 2.05 kΩ
    A12-1 - A12-2
    25°C (77°F)
    1.38 to 1.64 kΩ
    A12-1 - A12-2
    30°C (86°F)
    1.11 to 1.32 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the evaporator temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE EVAPORATOR TEMPERATURE SENSOR
OK


3.CHECK HARNESS AND CONNECTOR (EVAPORATOR TEMPERATURE SENSOR - A/C AMPLIFIER)


    E124472E09
  1. Disconnect the evaporator temperature sensor connector.



    E143742E34
  1. Disconnect the A/C amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A9-34 (TE) - A12-2
    Always
    Below 1 Ω
    A9-22 (SG-4) - A12-1
    Always
    Below 1 Ω
    A9-34 (TE) - Body ground
    Always
    10 kΩ or higher
    A9-22 (SG-4) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE A/C AMPLIFIER