P0705
| (A) Any 2 or more signals of the following are ON simultaneously (2-trip detection logic)
- P input signal is ON.
- N input signal is ON.
- R input signal is ON.
- D input signal is ON.
(B) Any 2 ore more signals of the following are ON simultaneously (2-trip detection logic)
- NSW input signal is ON.
- R input signal is ON.
- D input signal is ON.
(C) Any of following conditions is met for 2.0 sec. or more in the S position (2-trip detection logic).
- NSW input signal is ON.
- P input signal is ON.
- N input signal is ON.
- R input signal is ON.
(D) All switches are OFF simultaneously for NSW, P, R, N and D.
| - Open or short in park/neutral position switch circuit
- Park/neutral position switch
- ECM
|