DTC P0710 Transmission Fluid Temperature Sensor "A" Circuit |
DTC P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input |
DTC P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0710 | (a) and (b) are detected momentarily within 0.5 sec. when neither P0712 nor P0713 is detected (1-trip detection logic) (a) ATF temperature sensor resistance is less than 79 Ω. (b) ATF temperature sensor resistance is more than 156 kΩ. HINT: Within 0.5 sec., the malfunction switches from (a) to (b) or from (b) to (a) |
|
| P0712 | ATF temperature sensor resistance is less than 79 Ω for 0.5 sec. or more (1-trip detection logic) |
|
| P0713 | ATF temperature sensor resistance is more than 156 kΩ when 15 minutes or more have elapsed after the engine start DTC is detected for 0.5 sec. or more (1-trip detection logic) |
|
| Related DTCs | P0710: ATF temperature sensor/Range check (Chattering) P0712: ATF temperature sensor/Range check (Low resistance) P0713: ATF temperature sensor/Range check (High resistance) |
| Required sensors/Components | ATF temperature sensor (TFT sensor) |
| Frequency of operation | Continuous |
| Duration | 0.5 sec. |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever these DTCs are not present. | None |
| The typical enabling condition is not available. | - |
| The monitor will run whenever this DTC is not present. | None |
| Time after engine start | 15 min. or more |
| TFT (Transmission fluid temperature) sensor resistance | Less than 79 Ω or More than 156 kΩ |
| TFT sensor resistance | Less than 79 Ω |
| TFT sensor resistance | More than 156 kΩ |
| TFT sensor. | Atmospheric temperature to approx. 130°C (266°F) |

| READ DATA LIST |
Warm up the engine.
Turn the ignition switch off.
Connect Techstream to the DLC3.
Turn the ignition switch to the ON position.
Turn on the tester.
Select the item "Powertrain / Engine and ECT / Data List".
According to the display on the tester, read the "Data List".
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| A/T Oil Temperature 1 | ATF Temp. Sensor Value/ min.: -40°C (-40°F) max.: 215°C (419°F) |
| If the value is "-40°C (-40°F)" or "215°C (419°F)", ATF temp. sensor circuit is opened or shorted. |
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or more | Short circuit |
| 1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR) |
![]() |
Disconnect the transmission wire connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 1 (THO) - 7 (E2) | 79 Ω to 156 kΩ |
| 1 (THO) - Body ground | 10 kΩ or higher |
| 7 (E2) - Body ground | ↑ |
| ATF Temperature | Specified Condition |
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector to the transaxle.
Disconnect the ECM connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| E10-24 (THO1) - E9-28 (E2) | 79 Ω to 156 kΩ |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| E10-24 (THO1) - Body ground | 10 kΩ or higher |
| E9-28 (E2) - Body ground |
|
| ||||
| OK | ||
| ||