DTC    P0710    Transmission Fluid Temperature Sensor "A" Circuit

DTC    P0712    Transmission Fluid Temperature Sensor "A" Circuit Low Input

DTC    P0713    Transmission Fluid Temperature Sensor "A" Circuit High Input

for Preparation Click here


DESCRIPTION

The ATF (Automatic Transmission Fluid) temperature sensor converts the fluid temperature into a resistance value which is input into the ECM.
The ECM applies a voltage to the temperature sensor through ECM terminal THO1.
The sensor resistance changes with the transmission fluid temperature. As the temperature becomes higher, the sensor resistance decreases.
One terminal of the sensor is grounded so that the sensor resistance decreases and the voltage goes down as the temperature becomes higher.
The ECM calculates the fluid temperature based on the voltage signal.
G031389E12

DTC No.
DTC Detection Condition
Trouble Area
P0710
(a) and (b) are detected momentarily within 0.5 sec. when neither P0712 nor P0713 is detected (1-trip detection logic)
(a) ATF temperature sensor resistance is less than 79 Ω.
(b) ATF temperature sensor resistance is more than 156 kΩ.
HINT:
Within 0.5 sec., the malfunction switches from (a) to (b) or from (b) to (a)
  1. Open or short in ATF temperature sensor circuit
  2. Transmission wire (ATF temperature sensor)
  3. ECM
P0712
ATF temperature sensor resistance is less than 79 Ω for 0.5 sec. or more (1-trip detection logic)
  1. Short in ATF temperature sensor circuit
  2. Transmission wire (ATF temperature sensor)
  3. ECM
P0713
ATF temperature sensor resistance is more than 156 kΩ when 15 minutes or more have elapsed after the engine start
DTC is detected for 0.5 sec. or more (1-trip detection logic)
  1. Open in ATF temperature sensor circuit
  2. Transmission wire (ATF temperature sensor)
  3. ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the automatic transmission fluid (ATF) temperature sensor (TFT sensor) circuit. The automatic transmission fluid (ATF) temperature sensor converts ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature, and the ECM detects an opens or shorts in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 79 Ω *1or more than 156 kΩ *2, the ECM interprets this as a fault in the ATF sensor or wiring. The ECM will turn on the MIL and store the DTC.
*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.
*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

HINT:
The ATF temperature can be checked on the Techstream display.


MONITOR STRATEGY


Related DTCs
P0710: ATF temperature sensor/Range check (Chattering)
P0712: ATF temperature sensor/Range check (Low resistance)
P0713: ATF temperature sensor/Range check (High resistance)
Required sensors/Components
ATF temperature sensor (TFT sensor)
Frequency of operation
Continuous
Duration
0.5 sec.
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS

P0710: Range check (Chattering)

  1. P0712: Range check (Low resistance) 
    The monitor will run whenever these DTCs are not present.
    None
    The typical enabling condition is not available.
    -

P0713: Range check (High resistance) 
The monitor will run whenever this DTC is not present.
None
Time after engine start
15 min. or more

TYPICAL MALFUNCTION THRESHOLDS


P0710: Range check (Chattering) 
TFT (Transmission fluid temperature) sensor resistance
Less than 79 Ω
or
More than 156 kΩ

P0712: Range check (Low resistance) 
TFT sensor resistance
Less than 79 Ω

P0713: Range check (High resistance) 
TFT sensor resistance
More than 156 kΩ

COMPONENT OPERATING RANGE


TFT sensor.
Atmospheric temperature to approx. 130°C (266°F)

WIRING DIAGRAM


G039665E09


INSPECTION PROCEDURE

HINT:
Using Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the value listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether apart is faulty or not.


READ DATA LIST
  1. Warm up the engine.

  2. Turn the ignition switch off.

  3. Connect Techstream to the DLC3.

  4. Turn the ignition switch to the ON position.

  5. Turn on the tester.

  6. Select the item "Powertrain / Engine and ECT / Data List".

  7. According to the display on the tester, read the "Data List".

    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    A/T Oil Temperature 1
    ATF Temp. Sensor Value/
    min.: -40°C (-40°F)
    max.: 215°C (419°F)
    1. After Stall Test;
      Approx. 80°C (176°F)
    2. Equal to ambient temperature when cold soak
    If the value is "-40°C (-40°F)" or "215°C (419°F)", ATF temp. sensor circuit is opened or shorted.

    HINT:
    When DTC P0712 is output and Techstream output is 150°C (302°F), there is a short circuit.
    When DTC P0713 is output and Techstream output is -40°C (-40°F), there is an open circuit.
    Measure the resistance between terminal THO1 (THO) and body ground.

    Temperature Displayed
    Malfunction
    -40°C (-40°F)
    Open circuit
    150°C (302°F) or more
    Short circuit

    HINT:
    If a circuit related to the ATF temperature sensor become open, P0713 is immediately set (in 0.5 second).
    When P0713 is set, P0711 cannot be detected.
    It is not necessary to inspect the circuit when P0711 is set.

1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)


    C113969E36
  1. Disconnect the transmission wire connector from the transaxle.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 (THO) - 7 (E2)
    79 Ω to 156 kΩ
    1 (THO) - Body ground
    10 kΩ or higher
    7 (E2) - Body ground
    ↑

    HINT:
    If the resistance is out of the specified range with either the ATF temperature shown in the table below, the driveability of the vehicle may decrease.
    ATF Temperature
    Specified Condition
    10°C (50°F)
    5 to 8 kΩ
    25°C (77°F)
    2.5 to 4.5 kΩ
    110°C (230°F)
    0.22 to 0.28 kΩ



NG
REPAIR OR REPLACE TRANSMISSION WIRE
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    G038618E15
  1. Connect the transmission wire connector to the transaxle.

  1. Disconnect the ECM connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    E10-24 (THO1) - E9-28 (E2)
    79 Ω to 156 kΩ

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    E10-24 (THO1) - Body ground
    10 kΩ or higher
    E9-28 (E2) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM