DTC B1431/31 Air Mix Damper Position Sensor Circuit (Passenger Side) |

| DTC No. | DTC Detection Condition | Trouble Area |
| B1431/31 | Open or short in power source circuit in air mix damper position sensor circuit. |
|

| 1.READ VALUE USING TECHSTREAM |
Connect Techstream to the DLC3.
Turn the ignition switch to the ON position and turn Techstream on.
Select the items below in the Data List, and read the display on Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Air Mix Damper Position (P) | Air mix damper position (Passenger side) / min.: -14%, max.: 113.5% | Damper is at "MAX. COOL": -5% Damper is at "MAX. HOT": 105% | - |
| Air Mix Damper Target (P) | Air mix damper target position (Passenger side) / min.: -14%, max.: 113.5% |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT AIR MIX CONTROL SERVO MOTOR |
![]() |
Remove the air mix control servo motor.
Disconnect the connector from the air mix control servo motor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A18-1 - A18-2 | Always | 4.2 to 7.8 kΩ |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A18-3 - A18-2 | MAX. COOL position | 3.4 to 6.2 kΩ |
| A18-3 - A18-2 | MAX. HOT position | 0.8 to 1.6 kΩ |
![]() |
As the air mix control servo motor moves from the cool side to the hot side, the resistance decreases gradually without interruption.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (AIR MIX CONTROL SERVO MOTOR - A/C AMPLIFIER) |
![]() |
Disconnect the connector from the A/C amplifier.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A9-27 (TPP) - A18-3 | Always | Below 1 Ω |
| A9-21 (SG-1) - A18-2 | Always | Below 1 Ω |
| A9-30 (S5-1) - A18-1 | Always | Below 1 Ω |
| A9-27 (TPP) - Body ground | Always | 10 kΩ or higher |
| A9-21 (SG-1) - Body ground | Always | 10 kΩ or higher |
| A9-30 (S5-1) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||