DTC B1432/32 Air Inlet Damper Position Sensor Circuit |

| DTC No. | DTC Detection Condition | Trouble Area |
| B1432/32 | Open or short in power source circuit in air inlet damper position sensor circuit |
|

| 1.READ VALUE USING TECHSTREAM |
Connect Techstream to the DLC3.
Turn the ignition switch to the ON position and turn Techstream on.
Select the items below in the Data List, and read the display on Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Air Inlet Damper Position | Air inlet damper position / min.: -14%, max.: 113.5% | Damper is at "RECIRCULATION": -10% Damper is at "FRESH": 110% Damper is at "HALF-RECIRCULATION": 35 to 75% | Open in the circuit: 50.0% |
| Air Inlet Damper Target | Air inlet damper target position / min.: -14%, max.: 113.5% |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT AIR INLET CONTROL SERVO MOTOR |
![]() |
Remove the air inlet control servo motor.
Disconnect the connector from the air inlet control servo motor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A16-1 - A16-2 | Always | 4.2 to 7.8 kΩ |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A16-3 - A16-2 | RECIRCULATION position | 3.6 to 6.7 kΩ |
| A16-3 - A16-2 | FRESH position | 0.6 to 1.1 kΩ |
![]() |
As the air inlet control servo motor moves from RECIRCULATION to FRESH, the resistance decreases gradually without interruption.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (AIR INLET CONTROL SERVO MOTOR - A/C AMPLIFIER) |
![]() |
Disconnect the connector from the A/C amplifier.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A9-28 (TPI) - A16-3 | Always | Below 1 Ω |
| A9-21 (SG-1) - A16-2 | Always | Below 1 Ω |
| A9-30 (S5-1) - A16-1 | Always | Below 1 Ω |
| A9-28 (TPI) - Body ground | Always | 10 kΩ or higher |
| A9-21 (SG-1) - Body ground | Always | 10 kΩ or higher |
| A9-30 (S5-1) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||