Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    B1441/41    Air Mix Damper Control Servo Motor Circuit (Passenger Side)

for Preparation Click here


DESCRIPTION

The air mix control servo motor (air mix damper servo sub-assembly) is controlled by the A/C amplifier.
The air mix control servo motor moves the air mix damper by rotating (normal, reverse) with electrical power from the A/C amplifier.
This adjusts the mix ratio of the air that passes through the evaporator and heater core and controls the air flow temperature. Air flow temperature changes when the air mix damper is moved to the target point. The target point can be detected by the air mix damper position sensor.

DTC No.
DTC Detection Condition
Trouble Area
B1441/41
Air mix damper position sensor value does not change even if A/C amplifier operates air mix control servo motor.
  1. Air mix control servo motor
  2. Harness or connector between air mix control servo motor and A/C amplifier
  3. A/C amplifier

WIRING DIAGRAM


I036322E26


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the ignition switch to the ON position and turn Techstream on.

  1. Select the items below in the Data List, and read the display on Techstream.

    Data List / Air Conditioner: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Air Mix Damper Position (P)
    Air mix damper position (Passenger side) / min.: -14%, max.: 113.5%
    Damper is at "MAX. COOL": -5%
    Damper is at "MAX. HOT": 105%
    -
    Air Mix Damper Target (P)
    Air mix damper target position (Passenger side) / min.: -14%, max.: 113.5%

    OK:
    When the target position is "MAX. COOL" (-5%), the actual opening angle is 19.0% or less.
    When the target position is "MAX. HOT" (105%), the actual opening angle is 81.0% or more.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE A/C AMPLIFIER
A


2.PERFORM ACTIVE TEST USING TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the ignition switch to the ON position and turn Techstream on.

  1. Select the item below in the Active Test and then check the air flow temperature by hand.

    Active Test / Air Conditioner: 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Air Mix Damper (P Side)
    Air mix damper (Passenger side)
    min.: -14%, max.: 113.5%
    -

    OK:
    When the lever is moved to the "MAX. HOT" side, warm air comes out.
    When the lever is moved to the "MAX. COOL" side, cool air comes out.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE A/C AMPLIFIER
A


3.PERFORM ACTUATOR CHECK
  1. Enter the actuator check mode (Click here).

  1. Press the DEF switch and change to the step operation.

  1. Check the air flow temperature by hand.

    Display Code
    Air Mix Damper Operation
    0
    "COOL" side (-5%)
    1
    "COOL" side (-5%)
    2
    "COOL" side (-5%)
    3
    "COOL" side (-5%)
    4
    "COOL"/"HOT" (50.0% opened)
    5
    "COOL"/"HOT" (50.0% opened)
    6
    "HOT" side (105%)
    7
    "HOT" side (105%)
    8
    "HOT" side (105%)
    9
    "HOT" side (105%)

    OK:
    Air flow temperature changes in accordance with each display code.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE A/C AMPLIFIER
A


4.INSPECT AIR MIX CONTROL SERVO MOTOR


    E109236E13
  1. Remove the air mix control servo motor.

  1. Disconnect the connector from the air mix control servo motor.

  1. Connect the positive (+) lead from the battery to terminal 5 and the negative (-) lead to terminal 4, then check that the lever turns to the "MAX. HOT" position smoothly.

    OK:
    Lever turns to "MAX. HOT" position smoothly.

  1. Connect the positive (+) lead from the battery to terminal 4 and the negative (-) lead to terminal 5, then check that the lever turns to the "MAX. COOL" position smoothly.

    OK:
    Lever turns to "MAX. COOL" position smoothly.



NG
REPLACE AIR MIX CONTROL SERVO MOTOR
OK


5.CHECK HARNESS AND CONNECTOR (AIR MIX CONTROL SERVO MOTOR - A/C AMPLIFIER)


    E145121E09
  1. Disconnect the connector from the A/C amplifier.



    E143742E50
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A9-15 (AMPC) - A18-4
    Always
    Below 1 Ω
    A9-14 (AMPH) - A18-5
    Always
    Below 1 Ω
    A9-15 (AMPC) - Body ground
    Always
    10 kΩ or higher
    A9-14 (AMPH) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE A/C AMPLIFIER