DTC B1442/42 Air Inlet Damper Control Servo Motor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1442/42 | Air inlet damper position sensor value does not change even if A/C amplifier operates air inlet control servo motor. |
|

| 1.READ VALUE USING TECHSTREAM |
Connect Techstream to the DLC3.
Turn the ignition switch to the ON position and turn Techstream on.
Select the items below in the Data List, and read the display on Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Air Inlet Damper Position | Air inlet damper position / min.: -14%, max.: 113.5% | Damper is at "RECIRCULATION": -10% Damper is at "HALF-RECIRCULATION": 35 to 75% Damper is at "FRESH": 110% | Open in the circuit: 50.0% |
| Air Inlet Damper Target | Air inlet damper target position / min.: -14%, max.: 113.5% |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.PERFORM ACTIVE TEST USING TECHSTREAM |
Remove the glove box to see and check the recirculation damper operation.
Connect Techstream to the DLC3.
Turn the ignition switch to the ON position and turn Techstream on.
Select the item below in the Active Test and then check that the damper operates.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Air Inlet Damper Position (Linear) | Air inlet damper position (linear) | min.: -14%, max.: 113.5% | - |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 3.PERFORM ACTUATOR CHECK |
Remove the glove box to see and check the recirculation damper operation.
Enter the actuator check mode (Click here).
Press the DEF switch and check the operation of the recirculation damper.
| Display Code | Recirculation Damper Position |
| 0 | FRESH (110%) |
| 1 | FRESH (110%) |
| 2 | FRESH (110%) |
| 3 | R/F (50%) |
| 4 | RECIRCULATION (-10%) |
| 5 | RECIRCULATION (-10%) |
| 6 | RECIRCULATION (-10%) |
| 7 | RECIRCULATION (-10%) |
| 8 | RECIRCULATION (-10%) |
| 9 | RECIRCULATION (-10%) |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 4.INSPECT AIR INLET CONTROL SERVO MOTOR |
![]() |
Remove the air inlet control servo motor.
Disconnect the connector from the air inlet control servo motor.
Connect the positive (+) lead from the battery to terminal 5 and the negative (-) lead to terminal 4, then check that the lever turns to the "FRESH" position smoothly.
Connect the positive (+) lead from the battery to terminal 4 and the negative (-) lead to terminal 5, then check that the lever turns to the "RECIRCULATION" position smoothly.
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (AIR INLET CONTROL SERVO MOTOR - A/C AMPLIFIER) |
![]() |
Disconnect the connector from the A/C amplifier.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A9-17 (AIR) - A16-4 | Always | Below 1 Ω |
| A9-16 (AIF) - A16-5 | Always | Below 1 Ω |
| A9-17 (AIR) - Body ground | Always | 10 kΩ or higher |
| A9-16 (AIF) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||