Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    B1443/43    Air Outlet Damper Control Servo Motor Circuit

for Preparation Click here


DESCRIPTION

This circuit turns the servo motor and changes each damper position by receiving the signals from the A/C amplifier.
The air outlet damper servo motor switches the air outlet mode by rotating (normal, reverse) with electrical power from the A/C amplifier.
When the AUTO switch is on, the A/C amplifier changes the mode between "FACE", "FACE/FOOT" and "FOOT" according to the temperature setting.

DTC No.
DTC Detection Condition
Trouble Area
B1443/43
Air outlet damper position sensor value does not change even if A/C amplifier operates air outlet control servo motor.
  1. Air outlet control servo motor
  2. Harness or connector between air outlet control servo motor and A/C amplifier
  3. A/C amplifier

WIRING DIAGRAM


I036322E22


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the ignition switch to the ON position and turn Techstream on.

  1. Select the items below in the Data List, and read the display on Techstream.

    Data List / Air Conditioner: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Air Outlet Damper Position
    Air outlet damper position / min.: -14%, max.: 113.5%
    Damper is at "FACE": 0%
    Damper is at "FACE/FOOT": 33.5%
    Damper is at "FOOT": 53.5%
    Damper is at "FACE/DEF": 73.5%
    Damper is at "DEF": 100%
    Open in the circuit: 50.0%
    Air Outlet Damper Target
    Air outlet damper target position / min.: -14%, max.: 113.5%

    OK:
    When the target position is "FACE" (0%), the actual opening angle is 19.0% or less.
    When the target position is "DEF" (100%), the actual opening angle is 81.0% or more.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE A/C AMPLIFIER
A


2.PERFORM ACTIVE TEST USING TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the ignition switch to the ON position and turn Techstream on.

  1. Select the item below in the Active Test and then check that the air flow position by hand.

    Active Test / Air Conditioner: 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Air Outlet Damper Position (D Side)
    Air outlet damper position (Driver side)
    min.: -14%, max.: 113.5%
    -

    OK:
    Air comes out from the selected air outlet.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE A/C AMPLIFIER
A


3.PERFORM ACTUATOR CHECK
  1. Warm up the engine.

  1. Enter the actuator check mode (Click here).

  1. Press the DEF switch and change to step operation.

  1. Press the DEF switch and check the air flow by hand.

    Display Code
    Air Flow Condition
    0
    FACE (0%)
    1
    FACE (0%)
    2
    FACE (0%)
    3
    FACE (0%)
    4
    FACE (0%)
    5
    FACE/FOOT (33.5%)
    6
    FOOT (53.5%)
    7
    FOOT (53.5%)
    8
    FACE/DEF (73.5%)
    9
    DEF (100%)

    OK:
    Air outlet mode changes in accordance with each display code.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE A/C AMPLIFIER
A


4.INSPECT AIR OUTLET CONTROL SERVO MOTOR


    E147338E02
  1. Remove the air outlet control servo motor.

  1. Disconnect the connector from the air outlet control servo motor.

  1. Connect the positive (+) lead from the battery to terminal 4 and the negative (-) lead to terminal 5, then check that the lever turns to the "DEF" position smoothly.

    OK:
    Lever turns to "DEF" position smoothly.

  1. Connect the positive (+) lead from the battery to terminal 5 and the negative (-) lead to terminal 4, then check that the lever turn to the "FACE" position smoothly.

    OK:
    Lever turns to "FACE" position smoothly.



NG
REPLACE AIR OUTLET CONTROL SERVO MOTOR
OK


5.CHECK HARNESS AND CONNECTOR (AIR OUTLET CONTROL SERVO MOTOR - A/C AMPLIFIER)


    E145121E11
  1. Disconnect the connector from the A/C amplifier.



    E143742E41
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A9-40 (AOF) - A19-5
    Always
    Below 1 Ω
    A9-39 (AOD) - A19-4
    Always
    Below 1 Ω
    A9-40 (AOF) - Body ground
    Always
    10 kΩ or higher
    A9-39 (AOD) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE A/C AMPLIFIER