Home › ENGINE › 2GR-FE COOLING › COOLING FAN MOTOR

COOLING FAN MOTOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. NO. 1 COOLING FAN MOTOR


    A110242E05
  1. Check that the motor turns smoothly when the battery is connected to the fan motor connector.

  1. Measure the current while the motor is turning.

    Standard current:
    11.8 to 14.8 A at 20°C (68°F)

    If the result is not as specified, replace the No. 1 cooling fan motor.



2. NO. 2 COOLING FAN MOTOR


    A110241E05
  1. Check that the motor turns smoothly when the battery is connected to the fan motor connector.

  1. Measure the current while the motor is turning.

    Standard current:
    9 to 11 A at 20°C (68°F)

    If the result is not as specified, replace the No. 2 cooling fan motor.