1. INSPECT IGNITION SWITCH ASSEMBLY


    A160247E01
  1. Measure the resistance of the switch.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    -
    LOCK
    10 kΩ or higher
    1 (AM1) - 3 (ACC)
    ACC
    Below 1 Ω
    1 (AM1) - 3 (ACC)
    3 (ACC) - 2 (IG1)
    1 (AM1) - 2 (IG1)
    5 (AM2) - 6 (IG2)
    ON
    Below 1 Ω
    1 (AM1) - 2 (IG1)
    5 (AM2) - 6 (IG2)
    6 (IG2) - 4 (ST2)
    5 (AM2) - 4 (ST2)
    START
    Below 1 Ω

    If the result is not as specified, replace the switch assembly.