OCCUPANT CLASSIFICATION SYSTEM > INITIALIZATION |
| ZERO POINT CALIBRATION |
Zero point calibration and sensitivity check procedures.
Check that all of the following conditions are met:
Adjust the seat position according to the table below.
| Adjustment Component | Position |
| Slide Direction | Rearmost position |
| Reclining Angle | Upright position |
| Headrest Height | Lowest position |
| Lifter Height | Lowest position |
Turn the ignition switch to the LOCK position.
Connect the Techstream to the DLC3.
Turn the ignition switch to the ON position and turn the Techstream on.
Enter the following menus: Body Electrical / Occupant Detection / Utility / Zero Point Calibration.
Perform the zero point calibration by following the prompts on the tester screen.
| SENSITIVITY CHECK |
Sensitivity check procedures
Turn the ignition switch to the LOCK position.
Connect the Techstream to the DLC3.
Turn the ignition switch to the ON position and turn the Techstream on.
Enter the following menus: Body Electrical / Occupant Detection / Utility / Sensitivity Check.
Perform the sensitivity check by following the prompts on the tester screen.
Confirm that the beginning sensor reading within standard value.
Place a 30 kg (66.14 lb) weight (eg. a 30 kg (66.14 lb) of lead mass) onto the front passenger seat.
Confirm that the sensitivity is within the standard value.